Circuit overloading: 

Consideration should be given to the connection 

of the equipment to the power supply circuitry and the effect that any 
possible overloading of circuits might have on overcurrent protection and 
power supply wiring. Appropriate consideration of equipment nameplate 
ratings should be used when addressing this concern.

 

Ì

 Reliable  ground: 

Reliable grounding must be maintained at all times. To 

ensure this, the rack itself should be grounded. Particular attention should 
be given to power supply connections other than the direct connections to 
the branch circuit (i.e., the use of power strips, etc.).

Rack Mounting Instructions

To mount the appliance to the rack you need the delivered rack-mount 
brackets. There are a variety of rack units on the market, which may mean 
the assembly procedure will differ slightly. You should also refer to the 
installation instructions that came with the rack unit you are using.

Important Note: 

Make sure you use the screws supplied with the rack-mount 

brackets. Using the wrong screws could damage the hardware appliance and 
would invalidate your warranty. The rack model UTM 425 is not delivered 
with rails. Please observe the mounting instructions for your rack.

1. Attach the rack-mount brackets to the appliance

Place the appliance on a hard, flat surface with the front panel facing you.

Attach the rack-mount brackets to the left and right side of the appliance 
with the supplied screws.

Make sure the brackets are properly attached to the appliance.

2.  Choose the rack location:

Leave enough clearance in front of the rack so that you can open the front 
door completely (~60 cm/25 inches). Leave approximately 80 cm/30 inches 
of clearance in the back of the rack to allow for sufficient airflow and ease in 
servicing. This product is for installation only in a restricted access location 
(dedicated equipment rooms, service closets and the like).

3. Slide the appliance into the rack.

4.  Attach the brackets to the rack with the appropriate screws (not 

included).

Summary of Contents for UTM 425

Page 1: ...Operating Instructions Sophos UTM 425...

Page 2: ...The following symbol and its meaning appears in the Hardware Quick Start Guide Security Notes and in these Operating Instructions Caution and Important Note If these notes are not correctly observed T...

Page 3: ...D Hard disk access LEDs on each Ethernet connector Link LED Green Constantly 1 The Ethernet port is receiving power 2 Good connection between the Ethernet port and hub Off 1 The adapter and switch are...

Page 4: ...uding the HTTP proxy cache the entire email queue accounting and reporting data passwords and uninstalled Up2Date packages The version of the software will not change That is all firmware and pattern...

Page 5: ...ll be displayed Are you sure With the up down keys you can select Yes y or No n 4 Press the Enter key to confirm your settings The reboot machine action will now start Starting shut down 1 Press the E...

Page 6: ...eral Server Precautions Review the electrical and general safety precautions that came with the components you are adding to your appliance Determine the placement of each component in the rack before...

Page 7: ...t came with the rack unit you are using Important Note Make sure you use the screws supplied with the rack mount brackets Using the wrong screws could damage the hardware appliance and would invalidat...

Page 8: ...mum distance about 100 meters 1000 Base SX IEEE 802 3 1 Gbit s via fiberglass Multi mode fiberglass MMF cables can cover a distance of 500 550 m 1000 Base LX IEEE 802 3 1 Gbit s via fiberglass Here ex...

Page 9: ...onsole You can connect a serial console to the COM port of the Sophos UTM hardware appliances You can use for instance the Hyperterminal terminal program included with most versions of Microsoft Windo...

Reviews: