7.2.1. - Type of signal
The type of speed controlled pump is entered here.
Depending on the STDC
Version used various selections are possible:
(only
STDC
version 2 + 4)
Standard
: Speed control for standard pumps 230
AC on output R1.
Use only for standard pumps! PWM / 0-10V output switched off.
(only
STDC
version 3 + 4)
0-10V
: Speed control for special pumps via output V1 (e.g. High efficiency pumps) by
means of a 0-10V. Relay output R1 (
230AC) is switched on for power supply when
output V1 is switched on.
PWM
: Speed control for special pumps via output V1 (e.g. High efficiency pumps) by
means of a PWM signal. Relay output R1 (
230AC) is switched on for power supply
when output V1 is switched on.
7.2.2. -
Profile
In this menu, preconfigured profiles for various pumps can be selected. Alternatively,
all settings can be done manually. Please note that individual settings are still possible
even when a profile has been selected.
Special functions
7.2.3. - Output Signal
This menu determines the type of pump used: Solar pumps perform at their highest
power when the signal is also maxed, heating pump on the other hand are set to high-
est power when the control signal is at the lowest. Solar = normal, heating = Inverted.
Settings range: Normal, Inverted / Default setting: Normal