Sorensen MML Series Operation and Programming Manual
4-20
Examples
The following examples illustrate how to operate the module in CC mode.
1. Select Level1 (A) and Level2 (B)
There are two levels of each mode for you to select in static function. The level1 (A)
and level2 (B) can be selected through A/B key. Press A/B key to select current level1
or level2. When level1 (A) is selected, the LED of A/B key will be active. Press this
key again to select level2 (B), and the LED will be inactive.
2. Select Dynamic Function
There are two functions for CC mode: STATIC and DYNAmic. The two functions can
be selected through STATIC/DYNA key. Press STATIC/DYNA key to select Dynamic
function. Press this key again to select static function. When Dynamic function is
selected, the LED of DYNA will be active.
3. Short the Load Input
The Load can simulate a short circuit across the input. The short circuit will be
enabled when SHORT is pressed, and Load input is active (on). If the input is shorted,
the LED of short will be active. The SHORT key can be set in configuration of toggled
on/off mode, or active by pressing mode.
4. Load Input On/Off
The input can be toggled on or off by pressing LOAD. When the input is turned on,
the LED of load will be active.