Local Operation
4-21
4.3.2 Local Operation of Double Channels/Module (Panel B)
Figure 4-7 Double Channels/Module (Panel B)
The double channels/module means that there are two channels for one module.
Each channel of module is isolated from the other. One set of display/keypad for the
module can control both channels. The left channel is called channel L while the right
one channel R. The 7-segment LED displays one or two channel status. The keypad
and rotary knob can control both channels through R/L key.
c
7-segment LED Display
. Displays measurement V/I of single or double channels.
Each display has five digits.
d
Channel LED Indicators.
There are two LEDs to indicate the active right and/or
left channel(s) of the Load module. When the LED of channel R is on, the
7-segment display, mode, GO/NG indicators, and keypad are active on channel R.
Channel L functions the same as channel R when its LED indicator is on.
When the indicators of channel R and L are on, the 7-segment display selectively
shows both channels’ V or I. The indicators and STATIC/DYNA, SHORT, and
LOAD keys in operation mode will be disabled when both channels are selected.