Local Operation
4-23
Examples
The following examples illustrate how to select the double channels/module in CC
mode.
There are two channels/modules, so you have to select right or left channel for display
and keypad. When channel R and L are selected, only the R/L key is enabled; other
keys are disabled. During power-on, the preselected channel is channel L. It means
that the 7-segment display, indicators, and keypad are active at channel L. The double
channels/module has the same function as single channel/module. However, level 2(B)
cannot be selected.
1. The display sequence of R/L key is channel L -> channel R -> channels L+R
display V -> channels L+R I back to channel L.
2. Select Dynamic Function
The static and dynamic function can be selected through the STATIC/DYNA key. Press
this key to select Dynamic function, and press again to select static function. When
Dynamic function is selected, the LED of DYNAmic will be active.
3. Short the Load Input
The Load can simulate a short circuit across the input. The short circuit can be
enabled when SHORT is pressed, and Load input is active. When the input is shorted,
the LED of short will be active. The SHORT key can be set in configuration of toggled
on/off mode, or active by pressing mode.
4. Load Input On/Off
The input can be toggled on or off by pressing LOAD. When the input is turned on,
the LED of LOAD will be active.
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com