Remote Operation
5-15
Return Parameters: <NR1>
Query Example:
CHAN : SYNC?
Returns to the load module and makes it
receive synchronized command status.
Return Example:
0
The load module does not receive
synchronized command status.
1
The load module receives synchronized
command status.
CHAN:ID?
Type: Channel-specific
Description:
After going to a module, this query requests the module to identify
itself.
Query Syntax:
ID?
Return Parameters: <aard>
Query Example:
ID?
String
Information
Sorensen Manufacturer
80202
Model (2 x 100W module)
0
Always return zero
01.08
Revision of the primary interface firmware
0 Customer’s
Version
Return Example:
Sorensen,80202,0,01.08,0