Sorensen MML Series Operation and Programming Manual
5-18
CONFigure:VOLTage:LATCh
Type: Channel-specific
Description:
Sets the action type of Von.
Syntax: CONFigure:VOLTage:LATch
ON
CONFigure:VOLTage:LATch OFF
Parameters: ON/1,
OFF/0
Example:
CONF:VOLT:LAT ON
Sets the action type of Von as Latch.
CONF:VOLT:LAT OFF Sets the action type of Von as Non
Latch (for details, see Section 4).
Query Syntax:
CONFigure:VOLTage:LATch?
Return Parameters: <NR1>
Query Example:
CONF:VOLT:LAT?
Return Example:
0 (non latch), 1 (latch)
Returns the action type of Von.
CONFigure:AUTO:LOAD
Type: All
Channel
Description:
Sets if the load module will do Auto Load On during power-on.
Syntax: CONFigure:AUTO:LOAD
ON
CONFigure:AUTO:LOAD OFF
Parameters: ON/1,
OFF/0
Example:
CONF:AUTO:LOAD ON Starts Auto Load On during power-on.
CONF:AUTO:LOAD OFF Closes Auto Load On during power-on.
Query Syntax:
CONFigure:AUTO:LOAD?
Return Parameters: <NR1>
Query Example:
CONF:AUTO:LOAD?
Return Example:
0 or 1 Returns the status of Auto Load On
CONFigure:AUTO:MODE
Type: All
Channel
Description:
Sets type of Auto Load On as LOAD ON or PROGRAM RUN.
Syntax:
CONFigure:AUTO:MODE LOAD
CONFigure:AUTO:MODE PROGRAM
Parameters: LOAD/1,
PROGRAM/0
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com