Sorensen MML Series Operation and Programming Manual
5-22
CURRent:STATic:L1/L2
Type: Channel-specific
Description:
Sets Static Load Current of constant current mode.
Syntax: CURRent:STATic:L1
<NRf+>
[suffix]
CURRent:STATic:L2 <NRf+>
[suffix]
Parameters:
For valid value range, refer to respective specification.
Example:
CURR:STAT:L1 20
Sets Constant Current = 20A for Static
Load L1.
CURR:STAT:L2 10
Sets Constant Current = 10A for Static
Load L2.
CURR:STAT:L1 MAX Sets Constant Current = maximum
value for Static Load L1.
CURR:STAT:L2 MIN
Sets Constant Current = minimum value
for Static Load L2.
Query Syntax:
CURRent:STATic:L1?
CURRent:STATic:L2?
CURRent:STATic:L1? MAX
CURRent:STATic:L2? MIN
Return Parameters: <NR2> [Unit=Ampere]
Query Example:
CURR:STAT:L1?
Returns set current value of the Static
Load L1.
Return Example:
3.12