LOAD:SHORt:[STATe]
Type: Channel-specific
Description:
Activate or inactivate short-circuited simulation.
Syntax: LOAD:SHORt:[STATe]
Example:
LOAD:SHOR ON
Activates short-circuited simulation.
LOAD:SHOR OFF
Inactivates short-circuited simulation.
Parameters: ON/1,
OFF/0
Query Syntax:
LOAD:SHORt:[STATe]?
Return Parameters: <NR1>
Query Example:
LOAD:SHOR?
Returns the short-circuited simulation
state.
Return Example:
1
LOAD:SHORt:KEY
Type: Channel-specific
Description:
Sets the mode of short key in the electronic load.
Syntax: LOAD:SHORt:KEY
TOGGLE
Parameters: TOGGLE/1,
HOLD/0
Example:
LOAD:SHOR:KEY TOGGLE Sets short key mode as Toggle.
LOAD:SHOR:KEY HOLD
Sets short key mode as Hold.
Query Syntax:
LOAD:SHORt:KEY?
Return Parameters: <NR1>
Query Example:
LOAD:SHOR:KEY?
Returns the mode of short key in the
electronic load.
Return Example:
1