PIX 260i User Guide
75
Se
tup Menu Op
tions
#
Parameter Name
Description
Options
6
Sync Out
Determines whether the signal on the Sync Output
BNC is genlock or wordclock, and determines the
sync reference for that signal. When settings of a
resolution / frame rate are selected, the Sync Out
BNC will supply genlock signal at the specified rate
that reference the internal Ambient® Lockit.
» Off
• 1080p30
• 1080p29.97
• 1080p25
• 1080p24
• 1080p23.976
• 1080i60/PsF30
• 1080i59.94/PsF29.97
• 1080i50/PsF25
• 1080PsF24
• 1080PsF23.976
• 720p60
• 720p59.94 (29.97)
• 720p50
• 720p30
• 720p29.97
• 720p25
• 720p24
• 720p23.976
• 576i50 (PAL)
• 480i59.94 (29.97 NTSC)
• Genlock, Follows Video In
• Wordclock, Follows Video In
7
Auto-Record Hold Off
Sets the duration that a valid timecode sig-
nal has to be recognized by the PIX 260i
before generating a new take when using ex-
ternal timecode to trigger recording (When
[Remote Control - Rec Start/Stop]
is set to
Timecode
.
» 0 sec
(numeric 0-8)
8
Jam Received TC
Opens a dialog that displays incoming timecode
value in realtime (RxTC), incoming userbits (UB),
transmitting/internal (Ambient® Lockit) timecode value
(GENTC), and transmitting/internal userbits (UB).
• Push Control Knob to jam inter-
nal timecode to incoming (RxTC)
timecode.
• Push MENU to back out.
9
Jam time Of Day
Sets the internal timecode clock to the current time
of day.
10
Set Generator TC
Sets the Ambient® Lockit timecode generator value in
HH:MM:SS.FF format.
» 00:00:00.00
(Timecode value)
11
UBits Format
Sets the four-field format for the UBits Generator to
the default, which is user definable fields, or so that
the first three fields are automatically populated with
numerical values based on the system date.
When set to MM:DD:YY:UU or DD:MM:YY:UU, the
system will populate the first three fields, so those
fields will appear grayed out in the Set Generator
UBits menu option, leaving only the last field (UU) to
be customized daily by the user.
» UU:UU:UU:UU
• MM:DD:YY:UU
• DD:MM:YY:UU
12
Set Generator UBits
Sets userbits of the Ambient® Lockit timecode
generator.
» 00 00 00 00
(Hex: 00-FF for each slot)
13
File Start TC Offset
Sets the offset of the beginning timecode stamp of
recorded files. Useful when there is a constant offset
between camera and PIX 260i recorded files. The
applied offset does not affect timecode output of the
PIX 260i.
» 0
(numeric -10 to +10)