9
SL-6 POWERING AND WIRELESS SYSTEM
SL-6 DC Outputs
The SL-6 right panel features four DC power outputs via locking coaxial connec
-
tors (numbered 1 through 4) and a USB charging port. Outputs 1 through 4 are
12 V DC outputs that draw from the active SL-6 power source. Outputs 1 and 2
are isolated and do not share a common ground with the system.
To turn a DC output on or off:
1. Press the MENU button to access the Main menu.
2. Turn and press the Headphone encoder to select POWER > SL-6 Power Out
-
puts.
3. Turn and press the Headphone encoder to select an output and set it to On
or Off.
To protect NP-1 batteries from exceeding their maximum discharge current,
when total power draw reaches 45 watts, the 688 displays a warning message.
When total power draw reaches 50 watts (SWIT battery) or 53 watts (IDX bat
-
tery), the DC outputs will be turned off in descending order (output 4 - 1) until
power draw drops below 45 watts. First the USB charging port will be disabled,
then DC Output 4, DC Output 3, DC Output 2, and finally DC Output 1. You can
manually turn outputs back on when power draw drops below 45 watts.
SL-6 Power Settings
When the SL-6 is attached, the following settings are available in the Main
menu’s POWER section.
s
ub
-M
enu
n
aMe
D
escription
o
ptions
SL-6 Primary Source
Selects primary power source.
•
NP-1
•
DC Input
SL-6 NP-1 DC Ref
Calibrates the power level indicator
according to the type of NP-1 battery
in use. The default is 14V Li-ion.
•
14V Li-ion
•
NiMH
SL-6 DC Input Ref
Calibrates the power level indicator
according to the type of external DC
source. The default is 12V Ext DC.
•
12V Ext DC
•
NiMH
•
Expanded NiMH
•
12V Lead Acid
•
14V Li-ion
• Full Range
SL-6 Power Outputs
Sub-menu where each DC power out
-
put can be turned on or off.
•
Output 1 (12V Isolated)
•
Output 2 (12V Isolated)
•
Output 3 (Battery)
•
Output 4 (Battery)
•
USB Charging Port
Summary of Contents for SL-6
Page 4: ...SL 6 User s Guide 4 ...