background image

Packs A, B, C, F & G:

Before testing the system, ensure that all the 
batteries required for the transmitters are fully 
charged.
After checking all the connections and wiring, set 
the line and mic level controls to the half way point 
then connect the unit to the mains supply.
The Power LED on the ampli

fi

 er (of either a Panel 

Ampli

fi

 er or the IRX) will illuminate together with 

the green LEDs on any Outreach plates 

fi

 tted.  (If 

the green LEDs fail to illuminate, disconnect the 
supply and check the connections to the Outreach 
plates are correct.) 

For Packs A, B and C 

only

:

Set output level switch on the IWR-220 to MIC and 
switch the Receiver on; the red LED on the front 
panel should illuminate together with those 

fi

 tted 

to the external IR sensors. The 

fi

 xed  equipment 

should now be operating.

Next test the APA/APL input plate(s) by feeding in a low level signal from a music source such as a CD, MP3 or 
laptop. Set the volume control on the plate to maximum then adjust the line input on the Sound Panel ampli

fi

 er or 

IRX to produce a reasonable level over the room. 

Remember a Soundfield System is not a PA system

 - the objective is to provide a comfortable listening level over 

the entire room. In an empty room the system needs to be set slightly louder than would normally be required. Do 
not try to adjust the tone controls at this point.

If more than one plate of the same type has been installed, all should be tested using the same method. If different 
type Outreach plates have been installed, each should be tested using a suitable input source.

Now set up and test the infrared microphone transmitters using the procedures on pages 15 and 16. If the system 
includes an IWH-301 hand mic as well as a IWM-302 beltpack, then set the hand mic 

fi

 rst.

Testing and Commissioning

14

•  i-ceilings Powered Sound Panel controls and connectors

•  IRX Wallmount Ampli

fi

 er/IR Receiver controls and connectors

Summary of Contents for i-ceilings Pack B

Page 1: ...www soundfield uk com SYSTEM INSTALLATION GUIDE...

Page 2: ...and so large non reflective surfaces light absorbent surfaces such as black dark painted walls or large fabric coverage etc in the classroom which may reduce coverage must always be considered in the...

Page 3: ...ies for IWM 402 2 x Instructions Installation and Operation Manuals Pack F 4 x FBT Project 315 Wallmount Loudspeakers 1 x IRX Wallmount Amplifier IR Receiver 4 x 03284 Safety Cable 1 x IWM 402 Pendant...

Page 4: ...ble 10 10 Metre IR Sensor Extension Lead IWH 401 Handheld Transmitter Microphone 7W1B2V4 Rechargeable Battery for IWH 301A APA APL CD MP3 Laptop Wall Plate APA LLO Radio Assisted Hearing Aid Output Pl...

Page 5: ...ower Requirements Pack A B and C Systems A single 13 amp power point is all that is required as all ancillary Soundfield system items are powered directly from the panel amplifier If two speakers are...

Page 6: ...dfield system The plate is supplied with a 3 5mm 2pole jack socket with an output level of 775volts nominal set by means of a user adjustable level control Cable requirements are as Outreach input pla...

Page 7: ...the centre of the wall behind the teaching position and the same position on the opposite wall will give the best coverage see Diagram1 above alternatively position on opposite sides of the room The I...

Page 8: ...s used the amplifier is an integral part It supplies power to the IR receiver and any Outreach points as well as providing audio inputs and controls please refer to IAPA section for details on connect...

Page 9: ...eiver Both inputs have their own level controls An additional line level output 18v DC supply and external low impedance speaker output are also features of this unit The unit is fitted with High and...

Page 10: ...20 receiver only These terminals will provide a combined maximum output current of 500mA Line Output Balanced line level output terminals available on the IAPA for connection to the line level input o...

Page 11: ...V GND SPARE A OUT A OUT 18v 0v 18v 0v Optional NO MORE THAN 5 OUTREACH PLATES SHOULD BE CONNECTED MIC OUTPUTS OUTPUT LEVEL SET AT MIC SENSOR INPUTS DC IN IR RECEIVER 1 4 JACK POWER CONNECTOR R O S N E...

Page 12: ...w impedance Important note the speakers need to be wired in series parallel see diagram 4 Damage to the amplifierwilloccurifspeakerswithatotalimpedanceof less than 4 ohms are connected to these termin...

Page 13: ...cult to remove and avoids accidental disconnection of power Note If the mains cable needs to be disconnected from the IRX unit break the clear plastic cover on the red button of the rear of the IEC pl...

Page 14: ...vel signal from a music source such as a CD MP3 or laptop Set the volume control on the plate to maximum then adjust the line input on the Sound Panel amplifier or IRX to produce a reasonable level ov...

Page 15: ...ernatively adjust the level of the amplifier unit installed to compensate The microphone may be muted at at any time by pressing the mute button on the transmitter front if muted this will illuminate...

Page 16: ...t information Your IWM 402 is supplied with a set of rechargeable batteries However if these should become lost or require replacement it is critical that the following procedure is followed to allow...

Page 17: ...ive on Waste Electrical and Electronic Equipment 2002 96 EC the WEEE Directive For disposal details please go on line to www iceilings uk com weee htm 17 www soundfield uk com For further details on t...

Page 18: ...s However a number of acoustic factors lively noisy classes reverberant room conditions ambient noise from equipment outside hearing difficulties etc can have a significant effect on clear effective t...

Reviews: