background image

7

 Technical Data

Dimensions:

86mm (W) x 113mm (D) x 68mm (H)

Piower Supply:

230 V AC

DMX IN:

1 Unit Load

DMX OUT:

fed thru

Ballast Out:

1-10V DC Signal (current 

sink

, max. 25mA)

Order Code:

3044B-H

Disturbances

If a trouble-free operation cannot be guaranteed, disconnect the decoder interface and secure it
against unwanted operation. This is especially necessary, when
- the unit has visible damages;
- the unit does not operate;
- internal parts are loose;
- connection cables show visible damages.

CE Marking

The unit has been tested in our lab and has been marked to comply with CE
requirements. To ensure compliance, use grounded power leads only and make
sure that properly shielded data lines (CAT5, DMX data cable or Digital Audio cable
to AES/EBU specifications) are used. Any modifications not approved by the
manufacturer may void CE compliance.

Limited Warranty

This instrument ist warranted against defects in metarials and workmanship for a period of 12
month, beginning with the date of purchase. The warranty is limited to repair or exchange of the
hardware product; no further liability is assumed. SOUNDLIGHT is not responsible for damages or
for loss of data, sales or profit which arise from usage or breakdown of the hardware product. In
germany, SOUNDLIGHT  will repair or replace established defects in hardware, provided that the
defective part is sent in, freight paid, through the responsible dealer along with warranty card and/or
sales receipt prior to expiration of warranty.
Warranty is void:
- when modifying or trying to repair the unit without authorisation;
- modification of the circuitry;
- damages by interference of other persons;
- operation which is not in arccordance with the manual;
- connection to wrong voltage or current;
- misuse.

Service

There are no parts within the DMX DSI / DALI decoder 3004B-H which require the user's attention.
Should your unit require servicing, please send it to the factory, freight paid.

Summary of Contents for 3044BH

Page 1: ...TE HOWEVER SOUNDLIGHT DOES NOT ASSUME ANY RESPONSIBILITY FOR ERRORS OR OMISSIONS THEUSERHASTOCHECKTHESUITABILITYOFTHEEQUIPMENTFORTHEINTENDEDUSE SOUNDLIGHTEXPRESSLYEXCLUDESANYRESPONSIBILITYFORDAMAGES D...

Page 2: ...case of a loss of the drive signal the last setting will remain intact fully isolated data input Increased safety in case of system failure by optically isolated DMX data input cost effective The SOU...

Page 3: ...V Logic power supply 0 0V GND 10 nc do not use CN4 7 Control output to electronic ballasts EVG 1 orange channel 1 control signal 1 10V output 2 white channel 1 GND 0V 3 orange channel 2 control signal...

Page 4: ...of the first DMX data slot value 001 509 and decoder options must be programmed The start address switch board 3000P is required to set start address and mode of operation and decoder options NOTE Yo...

Page 5: ...being GND white resp light grey connector for all connected ballasts Usually terminals on the electronic ballasts are designated and respectively Then will mean GND Please note that the maximum output...

Page 6: ...connectors CN8 CN11 Power will be cutofwhentheassociatedDMXcontrolinputisdrivenwith000controlvalue Theoutputwillbeactivated for DMX data 001 thru 255 01 hex to FF hex Schematic individually powered an...

Page 7: ...trument ist warranted against defects in metarials and workmanship for a period of 12 month beginning with the date of purchase The warranty is limited to repair or exchange of the hardware product no...

Page 8: ...port soundlight de We will check your message and reply accordingly End of Liftetime Procedures Electronic devices are not domestic waste and must be disposed of properly If the end of lifetime of thi...

Reviews: