background image

EVCS_Remote  Node_ENGND04101  1.15       

1.800.338.7337 / www.soundoffsignal.com

NOTICE: 

Installers and users must comply with all applicable federal, state and local laws regarding use and installation of warning devices.

Improper use or installation may void warranty coverage. To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at

www.soundoffsignal.com/sales-support

. If you have questions regarding this product, contact 

Technical Services

, Monday - Friday, 8 a.m. to 5 p.m. at 

1.800338.7337

 (press #4 to skip the

automated message). Questions or comments that do not require immediate attention may be emailed to 

techservices@soundoffsigal.com.

SUPERIOR CUSTOMER RELATIONSHIPS. SMARTLY DESIGNED LIGHTING & ELECTRONIC SOLUTIONS.

1

Please see next page for 
Technical Specifications

REMOTE NODE

PART NUMBER: ENGND04101

The Remote Node provides 10 outputs for connection to

vehicle devices (50 Amps max).

 

•(4) 10-amp solid state switchable outputs

 

•(6) 5-amp solid state switchable outputs.

The Remote Node also provides 4 inputs to control systems.

 

•Active High/Low selectable.

 

See attached Install Template to aid in connections and programming

+

(Power)

-

(Ground)

Wire 

Pin #

Wire 

Function 

Amp

1

OUTPUT 9

10 Amp

2

OUTPUT 8

5 Amp

3

OUTPUT 7

10 Amp

4

OUTPUT 6

5 Amp

5

OUTPUT 5

5 Amp

6

OUTPUT 4

10 Amp

7

OUTPUT 3

5 Amp

8

OUTPUT 2

10 Amp

9

OUTPUT 10

5 Amp

10

INPUT 1

*

11

INPUT 2

12

INPUT 3

13

INPUT 4

14

ADDRESS 

SELECT

15

DATA

16

OUTPUT 1

5 Amp

PIN 1

PIN 8

PIN 16

PIN 9

OUTPUT INDICATOR LED’S 

FOR OUTPUTS 1-10

10

1

ADDRESS INDICATOR LED

DIAGNOSTIC INDICATOR LED

ACTIVE LOW

OR HIGH

MOMENTARY

ACTIVE HIGH

AUTOMOTIVE 50 

AMP MAX FUSE 

OR BREAKER

*Input 1 can be used as general purpose input   

  or as a system ignition input.

  Higher inrush current threshold - Xenon

V

BATT

DIRECT BATT GROUND 
CONNECTION

•HIGH CURRENT interconnects must be properly terminated.  Poor crimp quality can cause heat
  build-up and fire.  Follow crimp connector manufacturer instructions.
•DO NOT install this product or route any wires in the Air Bag Deployment Zone. Refer to vehicle 
  Owner’s Manual for deployment zones.
•Do NOT use system to disconnect headlights, brake lights or other safety equipment.
•Unit may become hot to touch during normal operation.
•Failure to properly install connectors, fuses or wiring may cause vehicle failure or fire.
•Installation must only be performed by trained technician.  Installer must determine vehicle wiring 
  configuration and proper integration of system.
•Use proper wire gauge.  All power wires connecting to positive (+) or negative (-) battery terminal 
  or local chassis ground (-) must be sized to supply at least 125% of max. current and properly fused at 
  power source.