DA-14 User Guide
Page 11
Environmental Specifications and Dimensions
Parameter
Specification
Dimensions
(less connectors)
5.2W x 1.62H x 6.625D
13.2 x 4.1 x 16.8 cm
Power
375 mA @ 6 Vdc
Operating Temp.
10 – 50
°
C
Operating Humidity
10 – 90% RH non-condensing
Inside the Module
In This Section
This section provides instructions for opening and closing the SoundPals DA-14 module to gain
access to the internal circuit board.
NOTE
The internal circuit board should only be removed from the module if you want to
reset the jumpers.
Before You Begin
Check the following items before opening the module and attempting to remove the internal
circuit board:
If required, remove the SoundPals module from the rack tray.
Disconnect the power supply from the front of the product.
Disconnect all input and output cables.
Perform the remaining steps
only
in a static free environment. Make sure that
you and
the product
are both grounded.
The following tools are required:
•
#2
Philips
screwdriver
Opening the Module
Use the following steps to open the DA-14 module:
1. On the rear panel, remove the four Phillips screws from the four corners of the
SoundPals module.
2. On the front panel, remove all Philips XLR mounting screws from the module.
3. On the front panel (if BNC connectors are present), remove the BNC nut(s) and
associated lock washer(s).
4. Pulling the rear panel, carefully draw the internal circuit board and rear panel assembly
from the housing.
CAUTION
If BNC connectors are present, keep the case horizontal so that the bushings
stay with the connectors.
5. Set the housing and all mounting hardware in a safe place.