background image

The symbol is used to indicate that some hazardous live terminals are involved within this apparatus, even 

under the normal operating conditions, which may be sufficient to constitute the risk of electric shock or 

death.

The symbol is used in the service documentation to indicate that specific component shall be replaced 
only by the component specified in that documentation for safety reasons.

Protective grounding terminal

Alternating current/voltage

Hazardous live terminal

ON:

 Denotes the apparatus is turned on

OFF:

 Denotes the apparatus is turned off.

WARNING:

 Describes precautions that should be observed to prevent the danger of injury or death to the operator.

CAUTION:

 Describes precautions that should be observed to prevent danger of the apparatus.

IMPORTANT SAFETY INSTRUCTIONS

·

Read these instructions.

·

Keep these instructions.

·

Heed all warning.

·

Follow all instructions.

Water & Moisture

·

The apparatus should be protected from moisture and 
rain, can not used near water, for example: near bath-
tub, kitchen sink or a swimming pool, etc.

·

Heat

The apparatus should be located away from the heat 
source such as radiators, stoves or other appliances 
that produce heat.

·

Ventilation

Do not block areas of ventilation opening. Failure to 
do could result in fire. Always install accordance with 
the manufacturer's instructions.

·

Object and Liquid Entry

Objects do not fall into and liquids are not spilled into 
the inside of the apparatus for safety.

·

Power Cord and Plug

Protect the power cord from being walked on or pinched  
particularly at plugs, convenience receptacles, and the 
point where they exit from the apparatus. 

Do not defeat the safety purpose of the polarized or 
grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong is provided for your safety. 
If the provided plug does not fit into your outlet, refer to 
electrician for replacement.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

IMPORTANT SAFETY SYMBOLS

·

Power Supply

The apparatus should be connected to the power supply 

only of the type as marked on the apparatus or described 
in the manual. Failure to do could result in damage to the 
product and possibly the user. 

Unplug this apparatus during lightning storms or when 
unused for long periods of time.

·

Fuse

To prevent the risk of fire and damaging the unit, please 
use only of the recommended fuse type as described in 
the manual. Before replacing the fuse, make sure the unit 
turned off and disconnected from the AC outlet.

·

Electrical Connection

Improper electrical wiring may invalidate the product war-
ranty.

·

Cleaning

Clean only with a dry cloth. Do not use any solvents such 
as benzol or alcohol.

·

Servicing

Do not implement any servicing other than those means 
described in the manual. Refer all servicing to qualified 
service personnel only.

·

Only use accessories/attachments or parts recommended 

by the manufacturer.

·

Warning

Please remember the high sound pressure do not only 
temporarily damage your sense of hearing, but can also 
cause permanent damage. Be careful to select a suitable 
volume.

Summary of Contents for NEOMIX-402UFX

Page 1: ...USER S MANUAL High quality compact mixing console with FX processor and USB soundcard NEOMIX 402UFX NEOMIX 802UFX...

Page 2: ...rotect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Do not defeat the safety purpose of the polarized o...

Page 3: ...stereo channels 6 2 2 4 Routing switch sole and channel fader 6 2 3 Connector panel and main section 6 2 3 1 Aux sends 1 and 2 6 2 3 2 Aux send connectors 1 and 2 7 2 3 3 Stereo aux return connectors...

Page 4: ...ase in class consoles combine the advantages of both analog and digital technology The NEOMIX Series represents a milestone in the develop 2 1 1 general mixing console functions A mixing console fulfi...

Page 5: ...The mid band is configured as a peak filter with a centre frequency of 2 5kHz Aux sends take signals via a control from one or more channels and sum these signals to a so called bus This bus signal i...

Page 6: ...ome recording level the input is more sensitive than at 4 dBu studio level BAL 4 The PAN control determines the position of the channelsignal within the stereo image This control features a constant p...

Page 7: ...be plugged into STEREO AUX RETURN 2 In this instance the FX control of the channel being used as an effects return should be turned fully counterclockwise otherwise feedback problems could occur STERE...

Page 8: ...end to display too low a signals level at frequencies above 1 kHz This is why for example a Hi Hat should only be driven as far as 10dB Snare drums should be driven to approx 0 dB To activate the PFL...

Page 9: ...s if you want to use the phantom power supply 2 4 Rear view of NEOMIX 402UFX NEOMIX 802UFX 2 4 1 main mix outputs Alt 3 4 outputs and control room outputs Fig 2 14 Main mix outputs Alt 3 4 outputs and...

Page 10: ...nly high grade cable Please use commercial RCA cables to wire the 2 track inputs and outputs You can of course also connect unbalanced devices to the balanced input outputs Use either mono plugs or en...

Page 11: ...ronically balanced approx 20 k 22 dBu EQ mono channels Low Mid High 80 Hz 15 dB 2 5 kHz 15 dB 12 kHz 15 dB EQ stereo channels Low Mid High 80 Hz 15 dB 2 5 kHz 15 dB 12 kHz 15 dB Aux sends Type Impedan...

Page 12: ...rk of FRENEXPORT SPA Via Enzo Ferrari 10 62017 Porto Recanati Italy WARRANTY AND SERVICE All SOUNDSATION products feature a limited two year warranty This two year warranty is specific to the date of...