background image

   13 PIN CONNECTOR 

SYSTEM PROGRAMMING - 

Menu 1

PAGE 12

INSTALL  MANUAL

 SYSTEM WIRING DETAILS

NOT USED 

GREEN/WHITE

GREEN/BLACK

PINK/WHITE

RED/WHITE

ORANGE/WHITE

ORANGE/BLACK

BROWN

GRAY

 PURPLE/WHITE

GRAY/BLACK

PURPLE

GREEN

OUTPUT FOR FACTORY ALARM RE-ARM

OUTPUT FOR FACTORY ALARM DIS-ARM

NEGATIVE  STARTER OUTPUT

OUTPUT FOR TRUNK RELEASE ACTIVATION

 NEGATIVE ACCESSORY OUTPUT/ AUXILIARY OUTPUT 2

AUXILIARY OUTPUT 1/ PROGRAMMABLE OUTPUT

BRAKE SWITCH INPUT (+) WHEN BRAKE IS PRESSED

HOOD PIN SWITCH INPUT

 TACH WIRE INPUT 

WAIT TO START (DIESEL VEHICLES)

NOT USED

NOT USED

BLK/WHT

1-GREEN/WHITE         Re-arm(-)

 (Programmable) - Supplies one .75 second pulse when locked 

and one .75 second pulse after remote start shutdown. Factory alarm re-arm/ RAP shutdown.

2-GREEN/BLACK        Dis-arm(-)

  - .75 second pulse when unlock button is pressed and one 

.75 second pulse before remote start activation. For factory alarm dis-arm/ “wake up”.

3-PINK/WHITE     

        

(-) Start/ Crank - 

Negative output during crank/ start.

4-RED/WHITE              Trunk Release(-)

 - Output will activate when the TRUNK button is held 

for at least 3 seconds. 

5- ORANGE/WHITE     2nd Acc (-) / Auxiliary Output 2 

(Programmable) - Ground output at the 

same time as the primary Accessory. output. This output can be programmed to activate as an 
auxiliary output when the trunk and start buttons are held. 

6- ORANGE/BLACK    Auxiliary Output 1/ Programmable Output 

 - Auxiliary Output 1 

Programmable to (-) Ignition/ Car Finder and Dome Light Supervision with Car Finder. 

7- BROWN                   Brake Switch input (+) - 

This wire must be connected to the wire at the 

brake switch that changes to 12volts when the brake is pressed. 

   

8- BLACK/WHT  NOT USED

9- GRAY                       Hood Pin Input (-) - 

Connect

 

this wire to the supplied hood pin switch. If 

ground is detected on this input the remote starter will not activate.

10- PURPLE/WHITE    Tach Wire Input (A/C) - 

This wire is

 

used to

 

 to detect when the vehicle 

has started. The Tach source is typically taken from a fuel injector, coil, coil pack or crank position 
sensor. The Tach wire is generally found as the opposite from the common wire at the coil or fuel 
injector.

11- GRAY/BLACK        Wait to Start Input (+ or -) 

(Programmable) - On diesel vehicles connect 

this wire to the wait to start or glow plug wire. The system will wait for the input to turn off then 
remote start. A start delay may also be programmed to avoid this connection.

12- PURPLE        NOT USED

13- GREEN          NOT USED

SYSTEM PROGRAMMING - 

Menu 1

PAGE 13

INSTALL MANUAL

 SYSTEM WIRING DETAILS

RS.3

RS.3

Summary of Contents for TARANTULA RS.3

Page 1: ...terference and 2 This device must accept any interference received including interference that may cause undesired operation CAUTION Changes or modifications not expressly approved by the part respons...

Page 2: ...Tach Tachless Learn Hybrid Mode QUICK VIEW PROGRAMMING 7 9 Enter Program Mode System Reset Menu 1 2 3 4 SYSTEM WIRING DETAILS 10 14 Connector Views Wiring Description INSTALLER NOTES 15 Page for Inst...

Page 3: ...D START OUTPUT DISARM OUTPUT PULSE WITH UNLOCK BEFORE START NOT USED DIESEL WAIT TO START or TRIGGER TO START TACH DETECTION INPUT CONNECT TO COIL INJECTOR BRAKE SWITCH INPUT 12VOLT WHEN BRAKE IS PRES...

Page 4: ...CK ORANGE 1 2 3 4 SELECTABLE PARK LIGHT OUTPUT OUTPUT TO ACTIVATE DOOR LOCK CIRCUIT OUTPUT TO ACTIVATE DOOR UNLOCK CIRCUIT OUTPUT FOR VOLTAGE INVERTER GROUND OUTPUT FOR BYPASS MODULE WHILE RUNNING OUT...

Page 5: ...MODULES USING THE DATA TO DATA TYPE CONNECTION THERE ARE 2 SELECTION TYPES THE DEFAULT SETTING IS FOR FORTIN MODULES THE SECOND IS FOR IDATA BYPASS MODULES IF THE BYPASS KIT IS A FORTIN PRODUCT SIMPLY...

Page 6: ...ybrid mode 1 This option requires a tach connection Once the vehicle starts the system will not monitor the tach input and stay running for 15 minutes Hybrid Mode 2 No Tach wire connection This settin...

Page 7: ...ss and Release the Program Switch to advance through the settings Confirmed by Park Lights Horn LED flashes 5 Press and hold the Program Switch to change the setting Confirmed by Park Lights Horn LED...

Page 8: ...DOOR LOCKS ENABLED 8 ARS 1 ONLY PASSIVE ARMING PASSIVE ST KILL FULL PASSIVE ARMING ENABLED PASSIVE SAFETY REARM ENABLED 9 ARS 1 ONLY SHOCK AUX SENSOR INTERNAL SHOCK DISABLED BOTH SENSORS DISABLED BOT...

Page 9: ...4 Flashes 4 Honks SYSTEM PROGRAMMING Menu 1 SYSTEM PROGRAMMING Menu 1 7 LEDS FLASH WHEN LOCKED ARMED LED FLASHES LEDS DO NOT FLASH WHEN LOCKED ARMED AUTO TACH TACHLESS SETTING LED FLASHES SETTING DESC...

Page 10: ...ER KILL ANTI GRIND OUTPUT PINK OUTPUT TO ACTIVATE IGNITION CIRCUIT PINK WHITE SELECTABLE OUTPUT DEFAULT SECOND IGNITION RED 30A HIGH CURRENT 12VOLT INPUT PURPLE OUTPUT TO ACTIVATE START CIRCUIT RED 30...

Page 11: ...essory or Start output Programmable Note This output does not switch to default when the system is reset PIN 6 PINK Ignition Output This wire will test 0V in the off and Accessory positions the switch...

Page 12: ...PURPLE WHITE GRAY BLACK PURPLE GREEN OUTPUT FOR FACTORYALARM RE ARM OUTPUT FOR FACTORYALARM DIS ARM NEGATIVE STARTER OUTPUT OUTPUT FOR TRUNK RELEASEACTIVATION NEGATIVEACCESSORYOUTPUT AUXILIARYOUTPUT...

Page 13: ...nder and Dome Light Supervision with Car Finder 7 BROWN Brake Switch input This wire must be connected to the wire at the brake switch that changes to 12volts when the brake is pressed 8 BLACK WHT NOT...

Page 14: ...ct bypass modules using the data to data type connection There are 2 selection types The default setting is set for FORTIN Bypass Module the second is for IDATA Bypass Modules 4 PIN DATA BYPASS The Th...

Page 15: ...SYSTEM PROGRAMMING Menu 1 PAGE 15 INSTALL MANUAL INSTALLER NOTES RS 3...

Page 16: ...ock Button on each of the remote s to be programmed See notes below if the remote is to be programmed for 2nd car or PADLOC The system will respond by flashing the park lights for each remote If conne...

Page 17: ...ress and release the Program Button Step 2 The system will respond with three park light flashes and the HORN will HONK the same number of times as the events in memory Maximum four events four honks...

Page 18: ...12volts 87 86 85 87a 30 87 86 85 87a 30 Alarm and or Starter Module Door lock Output Blue Green Vehicle s Lock Unlock Switch USE SPDT 12v Relay POSITIVE DOOR LOCK LOW CURRENT 12volts 12volts 87 86 85...

Page 19: ...or lock Output Blue Green Unlock Resistor Lock Resistor Lock Unlock Switch USE SPDT 12v Relay REVERSE POLARITY DOOR LOCK SYSTEM 12volts 12volts Alarm and or Starter Module Door lock Output Blue Green...

Page 20: ...website www security soundstream com tech support tech support soundstream com...

Reviews: