SYSTEM PROGRAMMING -
Menu 1
PAGE 4
INSTALL MANUAL
QUICK VIEW WIRE DIAGRAM
1
2
3
1
2
3
1
2
3
4
THERMISTOR/ INPUT TRIGGER TO START****
The thermistor can be installed in the engine compartment for engine temperature or in
under the dash for interior temperature. Must be connected prior to power-up to be
detected by the remote starter.
Position 1 or Position 2
GREEN
BLUE
NOT USED
N/A*
N/A
BLACK
ORANGE
1
2
3
4
SELECTABLE PARK LIGHT OUTPUT*****
OUTPUT TO ACTIVATE DOOR LOCK CIRCUIT (-)
OUTPUT TO ACTIVATE DOOR UNLOCK CIRCUIT (-)
OUTPUT FOR VOLTAGE INVERTER*
GROUND OUTPUT FOR BYPASS MODULE
(-) WHILE RUNNING OUTPUT (BYPASS TURN ON)
BY DEFAULT THE SYSTEM COMES WITH
THE PARK LIGHT JUMPER SET FOR
POSITIVE PARK LIGHT OUTPUT.
TO CHANGE THE SYSTEM TO A NEGATIVE
PARK LIGHT OUTPUT, PLACE THE JUMPER
IN THE NEGATIVE PARK LIGHT POSITION
SHOWN IN THE DIAGRAM.
(Position 2)
POSITIVE
PARK LIGHT
NEGATIVE
PARK LIGHT
SYSTEM PROGRAMMING -
Menu 1
PAGE 5
INSTALL MANUAL
NOTES
PLEASE NOTE
* THE CENTRE PIN OF THE KEYLESS CONNECTOR IS LOW CURRENT AND IS
DESIGNED TO SUPPLY POWER TO DOOR LOCK MODULES (DO NOT CONNECT TO
RELAYS) OVERLOADING THIS OUTPUT WILL DAMAGE THE MODULE!
**THIS CONNECTOR IS USED FOR THE
ARS .1
ALARM MODELS ONLY. A GROUND
PULSE TO THE BLUE WIRE WILL CAUSE THE ALARM TO BEEP 3 TIMES (WARN
AWAY). A GROUND PULSE TO THE GREEN WIRE WILL CAUSE THE ALARM TO
ACTIVE FOR 60 SECONDS (FULL TRIGGER) THIS INPUT CAN BE USED FOR AN
ADDITION SENSOR SUCK AS A RADAR, GLASS BREAK OR AN EXTRA SHOCK
SENSOR. THIS INPUT IS TURNED ON AND OFF WITH THE MAIN SHOCK SENSOR.
***THIS INPUT IS USED TO CONNECT BYPASS MODULES USING THE DATA TO DATA
TYPE CONNECTION. THERE ARE 2 SELECTION TYPES.
THE DEFAULT SETTING IS
FOR FORTIN™ MODULES. THE SECOND IS FOR IDATA™ BYPASS MODULES. IF THE
BYPASS KIT IS A FORTIN™ PRODUCT SIMPLY CONNECT TO THIS INPUT AND
PROGRAM THE BYPASS MODULE AS PER THE INSTRUCTIONS. WHEN INSTALLING
A IDATA™ BYPASS MODULES SET ENTER PROGRAM MODE AND SET THE MODULE
FOR IDATA™. (MENU 4, SETTING 4, OPTION 1).
****THE THERMISTOR WILL DETECT THE ENGINE OR INTERIOR TEMPERATURE OF
THE VEHICLE AND TRIGGER THE VEHICLE TO START WHEN IN COLD START MODE.
THE THERMISTOR MUST BE CONNECTED PRIOR TO POWER UP TO BE DETECTED
BY THE UNIT.
*****ALWAYS TEST AND CONFIRM THE PARK LIGHT POLARITY BEFORE MAKING
YOUR CONNECTION TO THE VEHICLE.
MANUAL TRANSMISSION VEHICLES MUST BE INSTALLED USING A MANUAL
TRANSMISSION MODEL.
REMOTE STARTER.
NEVER INSTALL A AUTOMATIC MODEL INTO A MANUAL
TRANSMISSION VEHICLE.
RS.3
RS.3
BYPASS MODULE DATA COMMUNICATION PORT***
The default setting is set for FORTIN™ Bypass Modules.