ST2826 Operation manual
Ver1.0
◇
131
comparison are different. But the electrical feature is same. So the description can be applied
to BIN comparison and list sweep comparison.
DC isolation output: the DC isolation output (pin1 to pin16) generates the isolation by the
optoelectronic coupler with the collector open. The output voltage on every line is set by the
pull-up resistance on the HANDLER interface board. The pull-up resistance is connected to
the internal voltage (+5v). or the external voltage(EXTV:+5v).
The electrical feature of the DC isolation output can be divided into 2 types shown in
Table 9-4.
Table 9-4 the electrical feature of the DC isolation output
9.2.3HANDLER Interface board circuit
The output circuit for the comparison result is shown in the figure 9-6 below.
the output
signal
the output rated voltage
the maximum
current
the reference ground for the
circuit
LOW
HIGH
compared
signal
/BIN1 - /BIN9
/AUX
/OUT
/PHI
/PLO
≤0.5V +5V--+24V
6mA
Internal pull-up voltage:
ST2826 GND
EXTV1
:
COM1
control signal
/INDEX
/EOM
/ALARM
≤0.5V +5V--+24V
5mA
Internal pull-up voltage :
ST2826 GND
EXTV2
:
COM2