ST2826 Operation manual
Ver1.0
◇
83
DC1
Reset the instrument
Send ―clear signal‖
DT1
Instrument trigger
Send trigger signal
C0
control
Send control information
7.2.2GPIB address
The range of the GPIB address on ST2826 is from 1 to 31.the setting for GPIB can refer
to the bus address field on the SYSTEM SETUP page with the SYSTEM menu key being
pressed.
7.2.3 GPIB Bus Function
The GPIB bus function is completed by the following commands:
ABORT I/O (IFC): stop the bus working. Don‘t receive the instrument information,
and reset the interface to the idle state.
CLEAR LOCKOUT/SET LOCAL: control the instrument. The instrument can work
at a remote place.
DEVICE CLEAR (SDC or DCL): clear the selected instruments or all the
instruments.
LOCAL (GTL): return the local control.
LOCAL LOCKOUT (LLO): lock the local command. When the remote instrument
receives this command, the local command will be locked.
REMOTE: set the instrument to remote mode.
SPOLL: configure the bus state.
SERVICE REQUEST: request the control signal.
7.2.4
(
SCPI
)
SCPI is new universal commands based on IEEE488.2-1987. (SCPI is
equivalent
to TMSL
that is Test and Measurement System Language used by HP Company in America.)
Summary of Contents for ST2826
Page 2: ......
Page 10: ......
Page 51: ...ST2826 Operation manual Ver1 0 41 Figure 3 15 ...
Page 61: ...ST2826 Operation manual Ver1 0 51 ...
Page 144: ...ST2826 Operation manual Ver1 0 134 Figure 9 8 the input circuit for control signal ...