11
MSH/MPH series
Power crimp contacts
Crimp contacts
Type
Size
Part number
Max.
Contact
Permissible cables
Ø A
Ø F
current A
resistance m
h
Section mm
2
AWG gage
contact
barrel
Male
20
M-20-MS
7
m
2
0,38 to 0,93
22 to 18
1,6
1,35
Female
K-20-MS
Male
16
M-16-MS
13
m
1,5
0,93 to 1,91
18 to 14
1,6
2,00
Female
K-16-MS
Male
12
M-12-MS
20
m
1,2
1,91 t o3,18
14 to 12
2,4
2,55
Female
K-12-MS
Reducing
20
MKMS-20-28
0,1 to 0,15
28 to 26
0,65
sleeves
MKMS-20-24
0,21 to 0,38
24 to 22
0,95
16
MKMS-16-26
0,15 to 0,6
26 to 20
1,2
MKMS-12-22
0,1 to 0,38
28 to 22
0,9
12
MKMS-12-18
0,38 to 0,93
22 to 18
1,40
MKMS-12-16
0,6 to 1,34
20 to 16
1,70
Contacts
Max.
Contact
Permissible cables
Ø A
Ø F
Type
Size
Part number
current A
resistance m
h
Section mm
2
contact
barrel
Flexible
Extra flexible
Male
8
M-8-MS
45
m
1
5,15 to 10
3,18 to 6
3,6
4,4
Female
K-8-MS
Male
6
M-6-MS
10
6
5
Female
K-6-MS
75
m
0,8
4,6
Male
6E
M-6E-MS
16
10
5,5
Female
K-6E-MS
Male
25C
M-25C-MS
25
16
7,7
Female
K-25C-MS
120
m
0,5
6,7
Male
25CE
M-25CE-MS
35
25
9
Female
K-25CE-MS
Male
50MC
M-MS-50MC
170
m
0,3
50
40
8
10,3
Female
K-MS-50MC
Réducing
8
MK-MS-8-12
3,18 to 5,15
3,4
sleeve
Pin
Socket
Reducing sleeve
Pin
Socket
Reducing sleeve