background image

6

MSH/MPH series

Features Benefits

Mechanical 

• Square threaded screw coupling

• High vibration and shock withstanding.

(plug on receptacle).

• Suitable for Harsh Environment application

• Conical coupling interface.

(railways, mining, public works…).

• Special cone-design on backshell 

• Extreme resistance to pull out

for cable braid retention.

or transverse forces on cable (80 kg).

• 5 key mechanical polarisation.

• Reliable and safe mating.

• Scoop proof shells.

Environmental

• Oring sealing between plug and receptacle.

• High performance sealing:

- permanent IP68,

• Packing seal on backshell to cable interface.

- Permanent water immersion 

up to 2 meters,

• Cable boot on backshell interface.

- Compliance with main Marine 

and Heavy Industries cable.

• Tin plated Aluminium 

• High corrosion resistance

or Marine bronze shells

(salt spray, sea water, sand, dust, 

hydrocarbons fluids…).

• RoHS compliant.

Electrical

• Dismountable crimp contacts.

• Easy wiring.

• Growding ring on plug side.

• EMI/RFI/protection.

Features and benefits

The very ruggedized design of MSH/MPH series brings the following benefits :

Summary of Contents for MPH Series

Page 1: ...Connectors for Navy Applications and Heavy Duty Industries MSH MPH SERIES...

Page 2: ......

Page 3: ...on 4 Applications 5 Description 7 Schematic 8 Characteristics 10 Contacts 1 1 Polarization keys 1 5 Cable codes 1 5 References 16 Contact layouts 1 7 Dimensions 20 Spare parts 27 Tools 28 Wiring instr...

Page 4: ...are listed in GAM T1 and MAT 6840005 Two series are available These series are available with 8 shell sizes and large variety of layouts including signal power and RF conntacts New Cadmium Free plati...

Page 5: ...gas or petrol exploitation heavy plant power units inter carriage connections power supply racks trackside beacons power supply units cranes heavy plant tunneling machines concreting power supply uni...

Page 6: ...op proof shells Environmental Oring sealing between plug and receptacle High performance sealing permanent IP68 Packing seal on backshell to cable interface Permanent water immersion up to 2 meters Ca...

Page 7: ...ture of the cable on leaving the connector 1 E44 type receptacle body 2 Insulator collar 3 Rear insulator 4 Intermediate insulator 5 Contact retaining clips 6 Flat gasket for square flange receptacle...

Page 8: ...MSH MPH series General configuration For single or multi contact signal coaxial and power layouts with pins of less than 8 mm diameter To order accessory only add Z suffix to the P N See glossary page...

Page 9: ...ceptacle no accessory options rear axial nut E0 E0 Bulkhead TRE Plug sealing cap BF BF Plug sealing cap with eyelet lanyard BFC BFC Receptacle sealing cap BE BE Receptacle sealing cap with ring lanyar...

Page 10: ...Free fall 2 5 m Trampling m 80 kg Electrical Withstand voltage At normal pressure 1 500 V between contacts size 20 2500 V for the other contacts Insulation resistance Cabled plug M 104 Mh Cabled recep...

Page 11: ...5 to 0 6 26 to 20 1 2 MKMS 12 22 0 1 to 0 38 28 to 22 0 9 12 MKMS 12 18 0 38 to 0 93 22 to 18 1 40 MKMS 12 16 0 6 to 1 34 20 to 16 1 70 Contacts Max Contact Permissible cables A F Type Size Part numbe...

Page 12: ...6 Male 70C M 70C MS 70 60 12 5 65 Female K 70C MS 291 66 Male 70CE M 70CE MS 95 70 14 5 65 Female K 70CE MS 66 Male 95C M 95C MS 95 70 14 5 68 Female K 95C MS 352 m 0 05 14 66 Male 95CE M 95CE MS 120...

Page 13: ...MS 16MC 65 m 0 8 15 82 Max 4 6 6 Female K MS 16MC Male 25MC M MS 25MC 90 m 0 8 24 62 Max 5 7 7 8 Female K MS 25MC Male 35MC M MS 35MC 120 m 0 5 34 67 Max 6 7 9 Female K MS 35MC Withstand Part number...

Page 14: ...75 1500 2 5 5000 m 8 RG302 0 7 CM 752 MS CK 752 MS RG179 1 7 2 3 2 7 CM 758 MS CK 758 MS 75PSB 3 8 4 8 6 5 OBT CM MS OBT CK MS Sealing plug Impedance h Miniature non watertight coaxial contacts Male...

Page 15: ...o 21 21 5 to 23 24 5 to 26 26 5 to 28 34 5 to 36 C1 9 to 10 12 to 13 13 to 14 5 18 to 19 5 20 to 21 5 23 to 24 5 25 to 26 5 33 to 34 5 D 8 to 9 11 to 12 12 to 13 16 5 to 18 18 5 to 20 21 5 to 23 23 5...

Page 16: ...eaktight cable clamp 2 SC 3 Non leaktight wire grip 2 SF 3 Thread mask backshell RZT Insulation type 6 Male M Female K Shell size 16 17 18 20 22 24 26 28 XX Connector series MSH connectors MPH connect...

Page 17: ...s shown in the normal position 1 1 C50A 1 C75A 3 3 C501 1 3 C502 3 C507 3 C508 50 h 3 C751 3 C752 3 C758 75 h 3 3 6 MC 3 8 3 10 MC 1 2 1 2 C50 2 Without contacts 1 2 C51 1 1 2 C51 2 1 2 C5 1 2 1 2 16...

Page 18: ...oaxial contacts 2 See Miniature coaxial contacts 3 3 8 3 6 MC 3 10 MC 3 3 16 MC 3 6 3 6E 3 3 25 MC 4 4 10 MC 4 8 48 48 20 24 3 3 35 MC 3 25C 3 25CE 1 2 1 2 C501 1 1 2 C502 1 2 C507 1 2 C508 50 h 1 2 C...

Page 19: ...nding contacts Note Do not use insulators with contacts from A 3 6 in plugs fitted with an elbow backshell RL z Note Do not use elbow backshell RL z or cable clamp SC z or wire grip SF z with these la...

Page 20: ...1 78 x 20 35 18 43 53 x 1 78 x 26 70 x 1 78 x 25 12 20 48 53 x 1 78 x 29 87 x 1 78 x 28 30 22 52 53 x 1 78 x 33 05 x 1 78 x 31 47 24 56 53 x 1 78 x 34 65 x 1 78 x 34 65 26 59 53 x 1 80 x 37 40 x 1 80...

Page 21: ...assembly of the receptacle Shell 1 A B C D E F G H K L M N Size Max Max Max 16 26 1 38 25 1 33 5 46 5 22 26 2 3 2 24 3 70 25 2 24 4 17 30 1 45 30 2 33 5 46 5 27 30 2 3 2 27 8 70 30 3 27 9 18 34 4 46 3...

Page 22: ...7 28 48 5 59 57 6 3 00 x 62 00 Shell A F G H Size Max B C D E 0 1 0 1 0 2 Flange seal 0 0 0 16 26 1 41 36 33 5 60 30 28 6 2 62 x 32 99 17 30 1 45 40 33 5 60 34 32 6 2 62 x 36 17 18 34 4 49 44 33 5 60...

Page 23: ...40 x 64 60 180 26 77 61 47 2 2 61 2 65 5 2 50 x 67 00 180 28 96 80 62 5 3 80 2 84 5 2 50 x 87 20 240 1 Please consult us regarding references other length Standard sealing caps BF and BE Shell size 1...

Page 24: ...5 mm Power single contact receptacle E33 Size x A x B x C D E F x G x H L Max x N max max 20 37 4 49 36 4 41 5 78 30 37 5 3 2 73 5 36 5 22 41 5 53 40 6 41 5 78 33 41 6 3 2 76 5 40 7 26 47 2 59 46 3 41...

Page 25: ...ptacle sealing caps Reference BF5 without lanyard Reference BF5C with lanyard 1 Except size 28 x 5 2 Example of part number BF5 MSH Shell Series 18 Straight watertight backshell RDZ Shell size F x G H...

Page 26: ...59 99 22 42 47 35 46 64 110 24 46 50 38 50 73 122 26 48 54 40 53 77 130 28 62 68 52 68 96 157 Dimensions Backshells Shell size L4 Max L5 Max x M 16 26 35 28 17 31 37 32 5 18 31 38 36 20 31 39 41 22 3...

Page 27: ...40 150 160 180 Spare parts Example of part number Cable boot Shell size Series see part number Cable code A to E1 see cable code 18 MSH A1 T Receptacle gasket Shell 16 17 18 20 22 24 26 28 size x A 25...

Page 28: ...rench Male Female M 8 MS BUCHANAN Positionneur OUT DBV M 10 MC OUT DBV K 10 MC K TGV 300 JAT T810 G M 6 MS K MACATRACTION MECATRACTION M 6 EMS TR 461 N ELS 460 OUT DBVM 16 MC OUT DBV K 16 MC K M MS 6...

Page 29: ...e Nominal section Crimping tool Dies Pin wrench M 50 C MS 50 mm2 TN 50 460 K MECATRACTION M 50 CEMS 60 mm2 MECATRACTION TN 60 460 DIN 1810 B K TR 1461 MECATRACTION M 70 C MS 70 mm2 TN 70 460 K MECATRA...

Page 30: ...lamping of braid grip Installation of miniature coaxial contacts Contact type Central contact External contact Removal CM 511 MS Pince BUCHANAN Pince BUCHANAN CM 512 MS M 22520 2 01 M 22520 4 01 JUPIT...

Page 31: ...e and bulkhead nuts 14 16 18 20 20 22 24 30 Tightening of plug locking nut Tightening torques mN Manual tightening Part No 771 20 42 Tightening using torque wrench Part No OUT 522 20 42 FACOM R305D or...

Page 32: ...tool Pull gently on the wire to check that the contact is firmly attached Removal Insert the wire into the channel on the plastic tool Slide the tool along the wire so that it enters the connector in...

Page 33: ...Before each crim ping or each soldering in the case of soldering contacts check that the conductor wire is clearly visible in the sight hole Fig 1 Insert the cable into the connector having taken car...

Page 34: ...34 14 1 16 1 18 5 20 27 x 20 C1 13 0 75 0 34 19 20 8 24 24 48 x 20 C1 18 0 75 0 34 22 24 27 26 61 x 20 C 28 0 75 0 34 26 6 28 6 32 28 85 x 20 D 1 1 1 07 0 75 6 3 8 6 10 5 16 3 x 20 C 3 1 07 0 75 11 2...

Page 35: ...0 34 17 5 19 5 22 5 26 61 x 20 D1 4 3 1 07 0 75 6 1 7 9 10 1 16 3 x 20 B1 5 1 07 0 75 7 5 9 3 11 5 16 5 x 20 B 7 1 07 0 75 7 7 9 5 12 1 16 7 x 20 A1 12 1 07 0 75 10 3 12 1 14 7 17 12 x 20 A1 19 1 07...

Page 36: ...nd multicoaxial cables Specific connectors and accessories The following products were manufactured by our design offices to meet the specific requirements of some connector users Please consult us fo...

Page 37: ...2850 PSI TP brass 300 m 425 PSI U stainless steel 300 m 425 PSI Souriau s global offer includes 5 product lines to meet marine oceanography markets requirements and very severe industry environments...

Page 38: ...Reliable Solutions www souriau com technical emear souriau com Europe Asia Africa technical americas souriau com North America Copyright SOURIAU July 2020 SOURIAU is a registered trademarks All infor...

Reviews: