For Machines Mfg. Since 5/11
13" Heavy 13
®
Gearhead Lathe
-85-
TROUBLESHOOTING
Symptom
Possible Cause
Possible Solution
Entire machine
vibrates upon
startup and while
running.
1.
Workpiece is unbalanced.
1.
Re-install workpiece as centered with the spindle
bore as possible.
2.
Loose or damaged V-belt(s).
2.
Re-tension/replace the V-belt(s) as necessary (see
Page 77).
3.
V-belt pulleys are not properly
aligned.
3.
Align the V-belt pulleys.
4.
Worn or broken gear present.
4.
Inspect gears and replace if necessary.
5.
Chuck or faceplate is unbalanced.
5.
Re-balance chuck or faceplate; contact a local
machine shop for help.
6.
Gears not aligned in headstock or
no backlash.
6.
Adjust gears and establish backlash.
7.
Broken gear or bad bearing.
7.
Replace broken gear or bearing.
8.
Workpiece is hitting stationary
object.
8.
Stop lathe immediately and correct interference
problem.
9.
Spindle bearings at fault.
9.
Reset spindle bearing preload or replace worn
spindle bearings.
Bad surface finish.
1.
Wrong spindle speed or feed rate.
1.
Adjust for appropriate spindle speed and feed rate.
2.
Dull tooling or poor tool selection.
2.
Sharpen tooling or select a better tool for the
intended operation.
3.
Tool height not at centerline.
3.
Adjust tool height to centerline (see Page 47).
4.
Too much play in gibs.
4.
Tighten gibs (see Page 75).
Tapered tool
difficult to remove
from tailstock quill.
1.
Quill is not retracted all the way
back into the tailstock.
1.
Turn the quill handwheel until it forces the tapered
tool out of quill.
2.
Contaminants not removed from
taper before inserting into quill.
2.
Clean the taper and bore and re-install tapered tool.
Cross slide,
compound, or
carriage feed has
sloppy operation.
1.
Gibs are out of adjustment.
1.
Adjust gib screw(s) (see Page 75).
2.
Handwheel is loose or backlash is
high.
2.
Tighten handwheel fasteners, adjust handwheel
backlash to a minimum (see Page 74).
3.
Leadscrew mechanism worn or out
of adjustment.
3.
Adjust leadscrew to remove end play (see Page 75).
Cross slide,
compound, or
carriage feed
handwheel is hard
to move.
1.
Dovetail slides loaded with
shavings, dust, or grime.
1.
Remove gibs, clean ways/dovetails, lubricate, and
re-adjust gibs.
2.
Gib screws are too tight.
2.
Loosen gib screw(s) slightly, and lubricate bedways
(see Page 75).
3.
Backlash setting too tight (cross
slide only).
3.
Slightly loosen backlash setting (see Page 75).
4.
Bedways are dry.
4.
Lubricate bedways and handles.
Cutting tool
or machine
components vibrate
excessively during
cutting.
1.
Tool holder not tight enough.
1.
Check for debris, clean, and retighten.
2.
Cutting tool sticks too far out of tool
holder; lack of support.
2.
Re-install cutting tool so no more than
1
⁄
3
of the total
length is sticking out of tool holder.
3.
Gibs are out of adjustment.
3.
Adjust gib screws at affected component (see Page
75)
4.
Dull cutting tool.
4.
Replace or resharpen cutting tool.
5.
Incorrect spindle speed or feed rate.
5.
Use the recommended spindle speed.
Summary of Contents for SB1049
Page 134: ......
Page 136: ...Printed In U S A TS14496...