19
20
SPA START-UP
FILLING THE SPA WITH WATER
4) Fill the spa to the bottom of the pillows or about 6-8 inches from the
top of the spa Note: DO NOT OVER-FILL YOUR TUB!
5) With the front panel off, verify there are no leaks at the pump union.
Note: Pump unions can become loose during shipping. Verify that there
are no leaks during filling of the spa.
TESTING THE GFCI BREAKER
NOTE: The electrical service panel for your spa should be equipped
with a GFCI breaker. To avoid the risk of electrical shock, perform the
following safety test before each use of your spa.
1) Make sure the power is turned on at the electrical service panel.
2) Turn on the GFCI breaker.
3) Press the test button. If the breaker turn off, reset the breaker. Break-
er is working properly. If the breaker does not turn off contact your elec-
trician.
DANGER: RISK OF ELECTRICAL SHOCK
If the GFCI breaker fails to operate as described, there is a possibility of
an electric shock if the spa is used. Shut off the power at the main elec-
trical service panel until the source of the problem has been identified
and corrected by a licensed electrician or qualified spa technician.
VS/GS SERIES CONTROL OPERATIONS
When your spa is first actuated, it will go into Priming mode which
is indicated by “Pr”. This Priming mode will last for 5 minutes and
then the spa will begin to heat the spa and maintain the water tempera-
ture in the Standard Mode.
TEMP/SET (80°F - 104°F / 26°C - 40°C)
The start-up temperature is set to 100°F/37°C. The last measured
temperature is constantly displayed on the LCD.
NOTE: The last measured spa temperature displayed is current
only when the pump has been running for at least 2 minutes.
To display the set temperature, press the “Cool”
or “Warm” pad once.
To change the set temperature, press the pad a second time before
the LCD stops flashing. Each press of the “Cool”
or “Warm” pad will
continue to either lower or raise the set temperature respectively.
LIGHT/MODE/FREEZE PROTECTION
LIGHT
Press the “Light” button to turn the light on and off. If
left on, the light automatically turns off after 4 hours.