FREEZE PROTECTION
If the temperature sensors detect a drop to below 44°F/6.7°C within
the heater, the pump will automatically activate to provide freeze
protection. The equipment stays on until 4 minutes after the sensors
detect that the spa temperature has risen to 45°F/7.2°C or
higher. In cold climates, an additional freeze sensor may be added
to protect against freeze conditions that may not be sensed by the
standard sensors. Aux freeze sensor protection acts similiarly except
with the temperature thresholds determined by the switch and
without a 4-minute delay in turnoff. See your dealer for details.
JETS/PRESET FILTER CYCLES
JETS
Touch the “Jets” button once to activate the pump for the
jets. Touch the “Jets” button
again to turn off the pumps. If left running, the pumps will automatically
turn off after 15 minutes.
21
22
DIAGNOSTIC MESSAGES
Temperature unknown.
After the pump has been running for 2 minutes, the
temperature will be displayed
“Overheat” The spa has shut down. One of the sensors
has detected 118°F/48°C at the heater.
DO NOT ENTER THE WATER. Remove the spa cover and
allow water to cool. Once the heater has cooled, reset by
pushing any button. If spa does not reset, shut off the power
to the spa and call your dealer or service organization.
“Overheat”-The spa has shut down. One of the sensors has
detected that the spa water is 110°F/43°C.
DO NOT ENTER THE WATER. Remove the spa cover
and allow water to cool. At 107°F/42°C, the spa should
automatically reset. If spa does not reset, shut off the power
to the spa and call your dealer or service organization
MODE
The mode is changed by pressing the “Warm”
or “Cool” button,
then pressing the “Mode” button.
Standard Mode
is programmed to maintain the desired temperature.
Note that the last measured spa temperature is current only
when the pump has been running for at least 2 minutes. “St” will be
displayed momentarily when you switch into Standard Mode.
Economy Mode
heats the spa to the set temperature only during
filter cycles. “Ec” will display solid when temperature is not current,
and will alternate when temperature is current.
Sleep Mode
heats the spa to within 20°F/10°C of the set temperature
only during filter cycles. “SL” will display solid when temperature
is not current, and will alternate when temperature is current.
PRESET FILTER CYCLES
The filter cycle begins 6 minutes after the spa is energized. The
second filter cycle begins 12 hours later. Filter duration is programmable
2, 4, 6, or 8 hours for continuous filtration (Indicated by “FC”).
The default filter time is 2 hours. To program,
press “Warm” or
“Cool” then “Jets”.
Press “Warm” or “Cool”
to adjust. Press “Jets” to exit programming.