240VAC WIRING SCHEMATIC
50 Hz ELECTRICAL SERVICE OPTIONS
3 Wires (1 Line + 1 N 1 Protective Earth)
Protective Earth wire (Green / Yellow) must be connected to system ground
terminal as marked.
This option is configured and shipped as the default.
All equipment (pumps, blower and heater) runs on service line L1
5 Wires (2 Lines + 2 Ne 1 Protective Earth)
Protective Earth wire (Green / Yellow) must be connected to system ground
terminal as marked.
The heater runs on service line L1, while all other equipment, such as
pumps and blowers, run on service line L2
Completely remove the white wire from J26 and J32
.
Note: J32 and J25 are electrically identical. The white wire may be at-
tached to either terminal before removal.
Single Service,
TN and TT
Electrical Systems
(1 X 16 Amp or 1 X 32 Amp)
Dual Service,
TN and TT
Electrical Systems
(2 x 16 Amp)
13
14