5
Glass Door Models
• Some glass door models have support brackets that need to be removed.
Auto-defrost Glass (ADG) Door Models
• Install condensate evaporator unit on rear of cabinet. Screwdriver is
required.
• Auto-defrost models with a condensate evaporator on the back should
not be placed directly against or touching a wall.
• Adequate space should be allowed around the exterior walls of the
merchandisers to allow for evaporation of any condensation that may
occur on cabinet exterior.
• Outdoor merchandisers should be located in a shaded area away from
direct sunlight for the most economical operation.
• A minimum 115 Volt, 15 Amp grounded power source should be provided
within a range of the power cord.
DO NOT USE EXTENSION CORDS.
Electrical
The electrical power supplied to the merchandiser must be as identified on the
serial number data plate located on the inside of the merchandiser. Electrical
service connections must be in accordance with the National Electrical
Code, state code and any local codes that may apply. All merchandisers
are equipped with a power cord and a 3-prong plug.
WARNING: Improper
use or removal of the grounding plug can result in a risk of electric shock!
Be sure to use a grounded electrical receptacle with a fused circuit sized correctly
for the electrical load.
Do not use extension cords.
Extension cords may decrease
the voltage to the unit and ultimately cause the compressor or other component
failure. The merchandiser data plate indicates the recommended maximum over
current protective device size.
Note: Some outdoor locations require ground fault interrupt (GFI) outlets. These
outlets may trip upon condensing unit start. Refrigeration equipment is exempt
in some areas from GFI requirements. Local electric codes should be checked.
Start Up
Plug merchandiser power cord into lower receptacle of electrical outlet. The
condensing unit will start immediately (electronically controlled models have a
delay on startup) and the unit cooler evaporator fans will start on the auto-defrost
models. The condensing unit will continue to run until air temperature inside the
BEFORE OPERATION
OPERATION