2.10 Jump / Booster Start
A. The safety precautions in the previous sections of this manual shall be read carefully before jump start. Jump
start is only an emergency measure taken when the battery capacity of unit is insufficient.
B. The battery may contain hydrogen and there shall be no flames, sparks or other sources of ignition around
the unit.
C. The electrolyte in the battery is highly corrosive and toxic. It cannot be in contact with the eyes, skin or fiber
surface. Otherwise, it will cause personal injury or property damage. Wear an acid-proof apron and a face mask
when implementing the bridging start.
D. Remove the ventilation cover of the unit battery and note not to let dust or other debris fall into the battery.
E. If the electrolyte is not enough, it should be added as required.
F. It can only be powered by a vehicle with the same battery system as the unit (direct grounding). The supplied
voltage shall be the same and the capacity is sufficient. It cannot be powered by generator, welder or other DC
power supply to avoid accidents.
G. The used jumper cable shall be clean and the rated current of the wire should be greater than the starting
current.
H. Avoid accidental contact between wire terminal, wire clamp and other metal parts to prevent a fire due to
electric arc.
I. Generally, the positive pole of the battery is marked with the words "+" and "POS", and the negative pole is
marked with the words "-" and "NEG".
J. Start the machine according to the normal procedure. Note not to continuously start the compressor for a long
time.
K. After the unit diesel engine is warmed up and operated smoothly at idle speed, disassemble the negative-pole
wire terminal connected to the unit, and then remove the other end from the battery negative pole of power
supply vehicle, and then remove another jumper wire from the positive pole of the unit battery. Finally, remove
the positive terminal on the power supply vehicle. Carefully remove the cables. Recover the vent cap of the
battery
2.11 Safety Warning
12.1 Unlike general routine inspection, the maintenance work (including refueling) shall be carried out
the compressor is not operating.
12.2 Remove and maintain the pressure components only after the compressor is stopped and all
pressure is released.
12.3 Do not use the open flame light source to check the internal side of equipment or pressure
container.
12.4 During repair and maintenance, general components shall be covered to protect against dust, and
the exposed components shall be covered with clean duster cloth, paper or insulating tape to keep clean.
12.5 Do not carry out welding or heating operation near the fuel oil or lubricating oil system. Before