I.  INTRODUCTION 
 

Before you begin installation of this fireplace, read these instructions completely. 

 

This fireplace and its components are safe when installed according to the installation manual. 

 

Unless Southwest Firebird Manufacturing/KIVA parts are used, which have been tested and approved for this  

 

fireplace, a firehazard may result. 

 

The Southwest Firebird Manufacturing/KIVA warranty will be voided and Southwest Firebird, Inc. disclaims any       
responsibility for the following infractions: 

1.  Any modification of the fireplace, components, doors, air inlet system, or damper control. 
2.  Use of any part not manufactured/approved  by Southwest Firebird Manufacturing Inc. 

 

PROPER PREPARATION prior to fireplace installation is very important to ensure  
safety and continuous operation. Consult the local building codes for specific 
requirements for your area. 

SELECTING A LOCATION 

To determine the safest and most efficient location for the fireplace the following guidelines must be taken into considera-
tion. 

1.  The location must allow for proper clearances

 

(See Pages 5 & 7). 

2.  The location of the fireplace should not be affected by drafts, air conditioning ducts, windows or doors. 
3.  A location where the cutting of joists, or roof rafters can be avoided. 
4.  The required outside air kit can be easily installed

 

(See Page 6).     

 

II.  FIREBOX INSTALLATION 

 

 

When installing the firebox, it must be placed on a level non-combustible surface.  If the existing floor surface is wood, vinyl 
or any combustible material, the flooring needs to be protected with ½” x 4’6”x 4’6” masonry board to the full dimension of 
the frame/cage (if used).  A minimum of 18” clearance from the firebox opening to any combustible is required.    

FOR YOUR SAFETY 

 

Do not store or use gasoline in the vicinity of this or any other appliance. 

 

Due  to  high  temperatures,  the  appliance  should  be  located  out  of  traffic  and away 
from furniture and draperies. 

 

Do not place clothing or other flammable materials on or near the appliance. 

 

NEVER leave children unattended when a fire is burning in the fireplace 

 

CHECK LOCAL CODES BEFORE INSTALLING THIS FIREPLACE. 

 

This wood burning fireplace complies with UL 127 standard as a FACTORY BUILT FIREPLACE. 

Warning this fireplace has not been tested with an unvented gas log set. To reduce risk of fire or injury, do 
not install an unvented gas log into fireplace 

 

 

WARNING

:  Do  not  install  fireplace  insert  in  this  firebox  unless  the  manufacturers  instructions  with  the  insert 

specifically state the Southwest Kiva fireplace has been tested for the insert. 

Summary of Contents for Kiva SWK24

Page 1: ...tractor or an installer certified by Southwest KIVA Inc Any permits required for installation should be obtained by contractor as well as any other construction industry inspections that may be requir...

Page 2: ...ystem 6 IV Chimney Installation 7 V Frame Installation 11 VI Door Frame Installation 11 VII Finishing Plastering the Fireplace 12 VIII Gas Pipe Installation 12 Parts List and Options 13 2 ALL PICTURES...

Page 3: ...doors 3 A location where the cutting of joists or roof rafters can be avoided 4 The required outside air kit can be easily installed See Page 6 II FIREBOX INSTALLATION When installing the firebox it...

Page 4: ...See Figure 3 To place the front of firebox bottom section make a mark on the centerline out from the corner according to Chart A Row D example Laguna 32 With a carpenter s square draw a perpendicular...

Page 5: ...the bottom section along the brick curve outlining the curve Remove the center section and spread refractory mortar 1 behind the line drawn on the bottom section Reset the center section press into po...

Page 6: ...n the frame area Using the sleeve of the vent as a template draw a 6 circle on the wall cut out the circle and insert the vent Secure the out side of the vent to the wall using 4 8 x 1 1 2 hex head se...

Page 7: ...construction needs to be 24 above the roof height parapet wall or roof peak The appropriate roof flashing should be secured to the top of the chase Note Any roof or floor decking should not cover any...

Page 8: ...il hem seats The outer section can now be installed Press down on outer section until the lances on the lower end securely engage and snap into the fireplace starting collar The wire spacer will assur...

Page 9: ...igure 16 6 Once the pipe run is complete install the flashing either secured to the roof or top of chase over the protruding pipe Next install the storm col lar around the exterior of the flue section...

Page 10: ...turn elbow Straps must be securely nailed to rafters joists or studs 3 Maximum lengths of pipe between supports return elbow or 12S 8DM is 6 of angled run Maximum of two 6 angled run sections per chim...

Page 11: ...with 6 x1 2 self drilling screws Once in place the mesh should be folded down on top of the hearth banco This mesh is also screwed to the frame with 6 x1 2 self drilling screws when the fireplace fram...

Page 12: ...ISHING PLASTERING THE FIREPLACE First plaster the interior of the kiva opening arch with a mortar mix of 1 part Portland cement 1 2 part lime 3 parts Vermiculite 1 2 cup by vol of shredded fiberglass...

Page 13: ...ugh the gas line sleeve If using a raised platform add height of platform to specified 8 1 2 inches Provide sufficient gas line into fireplace chamber for fitting connection NOTE Secure incoming gas l...

Page 14: ...ator Superior and Temco Firestop Spacer Flashing Chimney 12 18 24 36 48 Rain Cap Storm Collar 30 Degree offset FIREPLACE ACESSORIES Door Frame Part DF24 Outside Air OAK24 Damper Plate DP24 Chimney Sta...

Page 15: ...ock K Steel Frame L Firestop Spacer M Plaster Finish Minimum height of chim ney 11 1 2 Maximum height of chim ney 50 Banco Hearth 18 high x 18 wide Height of firebox w blocks 43 Clearance of Firebox t...

Reviews: