background image

7

Símbolos y Señalizadores

12070T

Operación

Voltios
Amperios
Corriente Alterna
Corriente Directa
Visualización de la Señal 
Ohmios
Continuidad
Prueba de Diodos
Faradios (capacidad)
Hertzio (frecuencia)
Grados Fahrenheit
Grados Centígrados 
Autorango (Rango automático)
Guardar la medida
Apagado automático
Altura Máxima Pico 
Altura Mínima Pico 
Registro Máximo 
Registro Mínimo 
Batería baja
nano (10

-9

)

micro (10

-6

milli (10

-3

kilo (10

3

)

mega (10

6

)

Sobrecarga 
 

10A

30 sec MAX

CAT III 1000V

CAT IV 600V

FUSED

MAX 400mA

Temp

Auto Power Off

Waterproof

every 15 min

mA

COM

Hz

CAP

®

12070T

!

Autoranging Multimeter

10A

30 sec MAX

CAT III 1000V

CAT IV 600V

FUSED

MAX 400mA

Temp

Auto Power Off

Waterproof

every 15 min

mA

COM

Hz

CAP

®

12070T

!

Autoranging Multimeter

8

Voltajes AC y DC 

1. Inserte la sonda negra en la toma de entrada negativa 

COM

.

2. Para medidas de corriente hasta 10A, mueva el interruptor

    rotatorio a la posición 

10A

 e inserte la sonda roja en

    la entrada positiva 

10A

.

3. Para medidas de corriente hasta 400mA, mueva el

    interruptor rotatorio a la posición 

mA

 e inserte 

    la sonda roja en la entrada positiva 

mA

.

4. Para medidas de corriente hasta 4000µA, mueva el

    interruptor rotatorio a la posición 

µA

 e inserte la sonda

    roja en la entrada positiva 

µA

5. Presione momentáneamente el botón 

MODO

 para

    seleccionar la corriente AC o DC. 

“AC” o “DC”

    aparecerá en la pantalla LCD.
6. Quite la corriente del circuito que se va a comprobar,

    luego abra el circuito en el punto donde se va a medir

    la corriente. 

Medidas de Corriente de AC y DC 

 

 

   Observe todas las precauciones de seguridad al

trabajar en voltajes activos.

ADVERTENCIA: 

 

 

   Observe todas las precauciones de seguridad al trabajar

en voltajes activos. No mida la corriente en circuitos que excedan los 1000V.

Medidas en el rango 10A deben ser limitadas a 30 segundos máx. cada

15 minutos.

ADVERTENCIA: 

V

CARGA

A

Operación

1. Mueva el interruptor rotario a la función de 

V

.

2. Presione momentáneamente el botón de

    

MODO

 para seleccionar el voltaje AC o DC.

    

“AC” o “DC”

 parecerá e la pantalla LCD.

3. Inserte la sonda negra en la toma de entrada

    negativa 

COM

 y la sonda roja en la toma de

    entrada positiva V.

4. Toque la punta de la sonda paralelamente al

    circuito que está bajo prueba. Para medidas

    de DC, toque la punta de la sonda roja al lado

    positivo del circuito y la punta de la sonda negra

    al lado negativo del circuito. 

5. Lea el voltaje de la pantalla LCD.

Summary of Contents for 12070T

Page 1: ...ciones de uso TESTING EQUIPMENT E361819 12 14 Rev 1 12070T manual Contents Made in China Product distributed by Southwire Company LLC One Southwire Drive Carrollton GA 30119 2014 Southwire Company LLC...

Page 2: ...attery compartment door firmly to maintain the waterproof and dust proof integrity of the meter Loose or overtightened screws or an improperly seated o ring may compromise the meter s water and dust i...

Page 3: ...ines to detached buildings Incoming service entrance from utility Outdoor pumps WARNING Operation is limited to CAT II applications when the insulated tips are removed from one or both test probes Ref...

Page 4: ...icon will be displayed on the LCD Momentarily press the HOLD button again to return to normal operation 6 Operation Backlight Button The backlight illuminates the display when the ambient light is too...

Page 5: ...rallel to the circuit under test For DC measurements touch the red test probe to the positive side of the circuit and the black test probe to the negative side of the circuit 5 Read the voltage on the...

Page 6: ...OL The resistance will be shown on the LCD display if it is below 400 10A 30 sec MAX CAT III 1000V CAT IV 600V FUSED MAX 400mA Temp Auto Power Off Waterproof every 15 min mA COM Hz CAP 12070T Autorang...

Page 7: ...s or an improperly seated o ring may compromise the meter s water and dust ingress protection WARNINGS To avoid electric shock do not operate your meter until the battery and fuse cover are in place a...

Page 8: ...mA 1 2 of rdg 5 digits 2 5 of rdg 5 digits Overload Protection FF500mA 1000V and F10A 1000V Fuse DC Current Auto ranging 400 0uA 4000uA 40 00mA 400 0mA 10A 0 1uA 1uA 10uA 100uA 10mA 1 0 of rdg 3 digit...

Page 9: ...tenance or repair operation outside of specifications or abnormal handling of the product Southwire s sole liability and the purchaser s exclusive remedy for any breach of this warranty is expressly l...

Page 10: ...AC rms 10A DC 1000VAC rms 1000VDC 1000VAC rms 1000VDC Lea entienda y siga todas las Reglas de Seguridad e Instrucciones de Operaci n en este manual antes de usar este metro Las caracter sticas de seg...

Page 11: ...binaci n del metro cables de pruebas y cualquier accesorio conectado al metro y cables de pruebas La combinaci n de clasificaci n es la M S BAJA de cualquier componente individual ADVERTENCIA El funci...

Page 12: ...neamente el bot n HOLD otra vez para regresar a la operaci n normal 6 Bot n de PEAK Hold Retenci n de picos La funci n Peak Hold captura el voltaje o corriente AC o DC m s alto Puede capturar alturas...

Page 13: ...positiva mA 4 Para medidas de corriente hasta 4000 A mueva el interruptor rotatorio a la posici n A e inserte la sonda roja en la entrada positiva A 5 Presione moment neamente el bot n MODO para sele...

Page 14: ...oximadamente 30 o menos sonar un tono Si el circuito est por encima de los 400 la pantalla indicar OL La resistencia aparecer en la pantalla si est por debajo de los 400 10 Prueba de Diodos Nunca comp...

Page 15: ...cubierta trasera y la puerta de compartimiento de la bater a para mantener la integridad de las caracter sticas de impermeabilidad y a prueba de polvo del metro Tornillos flojos o demasiado apretados...

Page 16: ...10uA 100uA 10mA 1 0 de la lectura 3 digitos 2 5 de la lectura 3 digitos Protecci n de Sobrecarga FF500mA 1000V y F10A Fusible 1000V Entrada M xima 4000uA DC en un rango uA 400mA DC en un rango mA 10A...

Page 17: ...uier incumplimiento de esta garant a est limitada expresamente a la reparaci n o reemplazo del producto por parte de Southwire La reparaci n o reemplazo del producto se har bajo la determinaci n de So...

Reviews: