Operation

HOLD button

To freeze the reading on the LCD display, press the HOLD button. The “

HOLD

” 

indicator will appear on the LCD display. Press the HOLD button again to return 

to normal operation.

Backlight      Button

The backlight illuminates the display when the ambient light is too low to permit 

viewing of the displayed readings. Press the backlight “    ” button to turn the 

backlight on. Press it again to turn the backlight off. 

V                 Volts
A                 Amps
-                  Minus sign

   

                AC voltage

                      DC voltage or current

Ω

                Ohms

µ                 micro (10

-6

m                milli (10

-3

)  

k                 kilo (10

3

                   Continuity
                   Diode test
BATT            Battery test
HOLD           Display hold
                   Battery status

Symbols and Annunciators

µA

mA

20

200

10A

1.5V

9V

2000

2000

200

200

20

k

k

k

BATT.

mA

mA

HOLD

COM

10A

For

30sec.

MAX

every

15 min

FUSED

2000

200

600

OFF

600

200

20V

2000

200

mV

mV

!

!

CAT 

III 

300V

6

Operation

µA

mA

20

200

10A

1.5V

9V

2000

2000

200

200

20

k

k

k

BATT.

mA

mA

HOLD

COM

10A

For

30sec.

MAX

every

15 min

FUSED

2000

200

600

OFF

600

200

20V

2000

200

mV

mV

!

!

AC Voltage Measurements 

DC Voltage Measurements 

 

              

Observe all safety precautions when working on live voltages.

WARNING:

 

 

               

Observe all safety precautions when working on live voltages.

WARNING:

 

1. Set the rotary function switch to the 

    600V     position.
2. Insert the black test lead into the 

    negative 

COM

 input jack and the red 

    test lead into the positive 

V

 input jack.

3. Touch the black test probe tip to the 

    negative side of the circuit. Touch the 

    red test probe tip to the positive side 

    of the circuit.
4. Read the voltage in the display. If necessary, 

    reset the function switch to successively  

    lower positions to obtain a higher 

    resolution reading. The display will indicate 

    the proper decimal point and value. If the 

    polarity is reversed, the display will show 

    (-) minus before the value.

1. Set the rotary function switch to the 

    600V~ position.
2. Insert the black test lead into the 

    negative 

COM

 input jack and the red 

    test lead into the positive 

V

 input jack.

3. Touch the test probe tips in parallel to 

    the circuit under test.
4. Read the voltage on the display. 

    If necessary, reset the function switch

    to successively lower positions to 

    obtain a higher resolution reading. The 

    display will indicate the proper decimal 

    point and value.

V

µA

mA

20

200

10A

1.5V

9V

2000

2000

200

200

20

k

k

k

BATT.

mA

mA

HOLD

COM

10A

For

30sec.

MAX

every

15 min

FUSED

2000

200

600

OFF

600

200

20V

2000

200

mV

mV

!

!

V

CAT 

III 

300V

CAT 

III 

300V

Summary of Contents for 10030S

Page 1: ...00 200 600 OFF 600 200 20V 2000 200 mV mV Instrucciones de uso 12 14 Rev 1 10030S manual Contents Made in China Product distributed by Southwire Company LLC One Southwire Drive Carrollton GA 30119 201...

Page 2: ...ot use the meter in wet or damp environments or during electrical storms Do not use the meter near explosive vapors dust or gasses Do not use the meter if it operates incorrectly Protection may be com...

Page 3: ...onent WARNING Operation is limited to CAT II applications when the insulated tips are removed from one or both test probes Refer to Input Limits section of this manual for maximum voltage ratings CAT...

Page 4: ...erve all safety precautions when working on live voltages WARNING 1 Set the rotary function switch to the 600V position 2 Insert the black test lead into the negative COM input jack and the red test l...

Page 5: ...serve all safety precautions when working on live circuits Do not measure current on circuits that exceed 250V Measurements in the 10A range should be limited to 30 seconds maximum every 15 minutes WA...

Page 6: ...ttery Test 1 Set the rotary function switch to the 1 5V or 9V BATT position 2 Insert the black test into the negative COM input jack and the red test lead into the positive V input jack 3 Touch the re...

Page 7: ...ts AC Voltage 200V 0 1V 600V 1V 1 2 reading 10 digits 50 60Hz 11 Operation Replacing the Fuses 1 Remove the two Phillips screws from the battery fuse door located on the back of the meter 2 Remove doo...

Page 8: ...product Whether Southwire repairs or replaces the product will be a determination that Southwire makes at its sole discretion SOUTHWIRE MAKES NO WARRANTY THAT THE PRODUCT WILL BE MERCHANTABLE OR FIT...

Page 9: ...ntalla LCD grande con luz de fondo Este metro est completamente compro bado y calibrado y bajo el uso apropiado proveer muchos a os de ZLY PJPV JVU HISL ADVERTENCIAS 3LH LU PLUKH ZPNH VKHZ SHZ 9LNSHZ...

Page 10: ...lasificaci n es la M S BAJA de cualquier componente individual ADVERTENCIA El funcionamiento est limitado a aplicaciones de CAT II cuando las puntas aisladas son retiradas de una o ambas sondas de pru...

Page 11: ...VERTENCIA 1 Mueva el interruptor rotario de funci n a la posici n de 600V 2 Inserte la sonda negra en la toma de entrada negativa COM y la sonda roja en la toma de entrada positiva V 3 Toque la punta...

Page 12: ...punto decimal apropiado y el valor Si la polaridad est invertida la pantalla indicar el signo de menos delante del valor Cumpla con todas las precauciones de seguridad al trabajar con circuitos activ...

Page 13: ...r una Bater a 1 Mueva el interruptor rotario de funci n a la posici n de 1 5V o 9V dependiendo del tipo de bater a 2 Inserte la sonda negra en la toma de entrada negativa COM y la sonda roja en la tom...

Page 14: ...0 1V 600V 1V 1 2 lectura 10 d gitos 50 60Hz 11 Cambio del Fusible 1 Retire dos tornillos Phillips de la cubierta de la bater a fusible 2 Retire la cubierta 3 Hale suavemente el fusible para retirarlo...

Page 15: ...DO PARA ALG N PROP SITO EN PARTICULAR SOUTHWIRE NO HACE NINGUNA OTRA GARANT A EXPRESA O IMPL CITA SALVO QUE LA GARANT A ESPEC FICAMENTE MENCIONADA EN ESTE P RRAFO SOUTHWIRE NO SER RESPONSABLE DE DA OS...

Reviews: