12
NOTE:
Accuracy is stated at 65
o
F to 83
o
F (18
o
C to 28
o
C) and less than 75% RH.
Specifications
Function Range Resolution Accuracy (% of reading)
DC Voltage
200mV 0.1mV
2000mV 1mV
20V 0.01V
200V 0.1V
600V 1V
±(0.5% r 2 digits)
±(0.8% r 2 digits)
DC Current
2000µA 1µA
20mA 10µA
200mA 100µA
10A 10mA
±(1.0% r 2 digits)
±(1.2% r 2 digits)
±(2.0% r 2 digits)
Resistance
200
Ω
0.1
Ω
2000
Ω
1
Ω
2Ok
Ω
0.01k
Ω
200k
Ω
0.1k
Ω
2000k
Ω
1
kΩ
±(0.8% r 4 digits)
±(1.0% r 2 digits)
Battery Test
9V 10mV
±(1.0% r 2 digits)
1.5 V 10mV
±(1.0% r 2 digits)
AC Voltage
200V 0.1V
600V 1V
±(1.2% r 10 digits)
50/60Hz
11
Operation
Replacing the Fuses
1. Remove the two Phillips screws from
the battery/fuse door located on the
back of the meter.
2. Remove door.
3. Remove the old fuse from its holder
by gently pulling it out.
4. Install the new fuse into the holder.
5. Always use a fuse of the proper size
and value (UL rated 0.2A /600V fast
blow for the 200mA range, UL rated
10A/600V fast blow for the 10A range).
6. Install battery/fuse door and tighten
screws.
To avoid electric shock, remove test leads from the meter
before removing the fuse door.
WARNING:
To avoid electric shock, do not operate your meter until
the fuse door is in place and fastened securely.
WARNING:
9V BATTERY
FUSE
FUSE