background image

9

Operation

Diode Test

  

 Never test diodes in a live circuit. 

WARNINGS:

 

Red

Probe

Red

Probe

Black

Probe

Black

Probe

1. Turn the rotary function switch to

    the 

Ω

            

CAP

 position.

2. Press the MODE button until the “      ”

    symbol appears on the LCD display.
3. Insert the black test lead into the negative

    

COM

 input jack and the red test lead into

    the positive 

Ω

 input jack.

4. Touch the test probes to the diode

    under test. Forward voltage will indicate

    0.4 to 0.7V. Reverse voltage will indicate

    “

OL

”. Shorted devices will indicate near

    0V and an open device will indicate “

OL

    in both polarities.

Forward test                 Reverse test

Continuity Test

 

               

Never test continuity on a live circuit.

WARNING:

 

1. Set the rotary function switch to the 

Ω

        

   CAP

 position.

2. Press the 

MODE

 button until the “    ” symbol

    appears on the LCD display. 
3. Insert the black test lead into the

    negative COM input jack. Insert the red

    test lead into the positive 

Ω

 input jack.

4. Touch the test probe tips to the circuit or

    wire you wish to check. 
5. If the resistance is approximately 30

Ω

 or

    less, an audible tone will sound. If the circuit

    is above 400

Ω

, the LCD display will indicate

   “

OL

”. The resistance will be shown on the

    LCD display if it is below 400

Ω

Wire

10

WARNING:

 

Operation

1. Set the rotary function switch to 

    the 

Ω

            position.

2. Press the

 MODE

 button until “

nF

    appears on the LCD display.
3. Insert the black test lead into the negative

    

COM

 input jack and the red test lead into

    the positive 

CAP

 input jack.

4. Touch the test leads to the capacitor

    being tested. 
5. Read the capacitance value on the LCD display.

    The meter will automatically adjust the reading

    ranges between pF, nF and uF. Large capacitors

    may take up to a minute to get a stable reading.

Capacitance Measurements

 

               

Safely discharge capacitors

before taking capacitance measurements. 

1. Set the rotary function switch to the 

Hz%

 position.

2. Press the 

Hz%

 button to select frequency or

    duty cycle. 

“Hz” 

or

 “%” 

will appear on the

    LCD display.
3. Insert the black test lead into the negative

    COM

 input jack and the red test lead into the

    positive 

Hz%

 input jack. 

4. Touch the test probe tips to the circuit under

    test.  
5. Read the frequency or % duty cycle on the

    LCD display. 

Frequency and % Duty Cycle Measurement   

Hz

 

               

Observe all safety precautions when working on live voltages.

WARNING:

 

Summary of Contents for 11060S

Page 1: ...Contents Made in China Product distributed by Southwire Company LLC One Southwire Drive Carrollton GA 30119 2014 Southwire Company LLC All rights reserved southwiretools com 1 855 SW T00LS Toll Free...

Page 2: ...be sure to secure the back cover panel and battery compartment door rmly to maintain the waterproof and dust proof integrity of the meter Loose or overtightened screws or an improperly seated o ring...

Page 3: ...ary distribution panels Overhead or underground lines to detached buildings Incoming service entrance from utility Outdoor pumps WARNING Operation is limited to CAT II applications when the insulated...

Page 4: ...red value 4 Press the REL button to return to normal operation HZ Button The HZ button is used to select frequency or duty cycle in when in the frequency voltage or current function When in the voltag...

Page 5: ...urrent AC or DC will appear on the LCD display AC and DC Current Measurements Observe all safety precautions when working on live voltages WARNING Observe all safety precautions when working on live v...

Page 6: ...ible tone will sound If the circuit is above 400 the LCD display will indicate OL The resistance will be shown on the LCD display if it is below 400 Wire 10 WARNING Operation 1 Set the rotary function...

Page 7: ...h a fresh 9V battery 5 Install battery door and tighten screws WARNING TO AVOID ELECTRICAL SHOCK REMOVE ALL INPUTS BEFORE OPENING THE CASE TO PREVENT FIRE INSTALL FUSE WITH AMP VOLT RATING SHOWN 9V BA...

Page 8: ...Fuse DC Current Auto ranging 400 0uA 4000uA 40 00mA 400 0mA 10A 0 1uA 1uA 10uA 100uA 10mA 1 0 of rdg 5 digits 2 5 of rdg 3 digits Maximum Input 4000uA DC on uA range 400mA DC on mA range 10A DC on 10A...

Page 9: ...tenance or repair operation outside of specifications or abnormal handling of the product Southwire s sole liability and the purchaser s exclusive remedy for any breach of this warranty is expressly l...

Reviews: