Specifications

Function                            Range           Resolution       Accuracy (% of reading)

Function                        Test Current       Resolution       Accuracy (% of reading)

Sensor: Type K Thermocouple

Overload protection: 1000V DC or AC rms.

Temperature 

-20°C~+760°C

-4°F~+1400°F

0.1°C 

0.1°F

± 3% of rdg ± 5°C 

± 3% of rdg ± 8°F

Open circuit voltage: MAX. 3V DC

Overload protection: 1000V DC or AC rms.

Diode Test

1 mA typical/

Open MAX. 3V

1mV

± 10% of rdg ± 5 digits

Audible continuity

Audible threshold: Approximately 30

Ω

 Test current Max.

1.5mA
Overload protection: 1000V DC or AC rms.

16

REGISTER YOUR PRODUCT

Register your product purchase at 

www.southwiretools.com

 or by scanning 

the QR code on this manual. At Southwire, we are dedicated to providing you 

with the best customer experience. By following a few quick steps to register, 

you can experience quicker service, more efficient support, and receive 

information on our future products. Simply provide your model number,

serial number, and just a few pieces of information about yourself –

it is that quick and easy. 

LIMITED WARRANTY AND LIMITATION OF LIABILITY ON

SOUTHWIRE METERS & TESTERS

Southwire Company, LLC warrants this product to be free from defects in 

material and workmanship for two years from the date of purchase. This 

warranty does not cover fuses, disposable batteries, or damage arising from an 

accident, neglect, misapplication, contamination, modification, improper 

maintenance or repair, operation outside of specifications, or abnormal 

handling of the product. Southwire’s sole liability, and the purchaser’s exclusive 

remedy, for any breach of this warranty is expressly limited to Southwire’s repair 

or replacement of the product. Whether Southwire repairs or replaces the 

product will be a determination that Southwire makes at its sole discretion.

SOUTHWIRE MAKES NO WARRANTY THAT THE PRODUCT WILL

BE MERCHANTABLE OR FIT FOR ANY PARTICULAR PURPOSE.

SOUTHWIRE MAKES NO OTHER WARRANTY, EXPRESSED OR

IMPLIED, OTHER THAN THE WARRANTY SPECIFICALLY SET FORTH 

HEREIN. SOUTHWIRE WILL NOT BE LIABLE FOR ANY INCIDENTAL,

CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES FOR

ANY BREACH OF THIS WARRANTY.  

This warranty is void if this product is used for rental purposes. No product 

reseller is authorized to extend any other warranty on Southwire’s behalf 

relating to this product, and no such reseller warranty will be binding on 

Southwire. If you have a warranty claim, or if the product needs to be

serviced during or after the warranty period set forth above, please contact

the Customer Service Department at 855-SWTOOLS (855-798-6657). 

The sender is responsible for all shipping, freight, insurance, and packaging 

costs associated with sending a product to Southwire. Southwire will not be 

responsible for lost or damaged products returned pursuant to this warranty.
All products returned to Southwire under this warranty should be mailed to: 

Southwire Company, LLC

Attention: Tool Warranty Return

840 Old Bremen Road

Carrollton, GA 30117

Summary of Contents for 11060S

Page 1: ...Contents Made in China Product distributed by Southwire Company LLC One Southwire Drive Carrollton GA 30119 2014 Southwire Company LLC All rights reserved southwiretools com 1 855 SW T00LS Toll Free...

Page 2: ...be sure to secure the back cover panel and battery compartment door rmly to maintain the waterproof and dust proof integrity of the meter Loose or overtightened screws or an improperly seated o ring...

Page 3: ...ary distribution panels Overhead or underground lines to detached buildings Incoming service entrance from utility Outdoor pumps WARNING Operation is limited to CAT II applications when the insulated...

Page 4: ...red value 4 Press the REL button to return to normal operation HZ Button The HZ button is used to select frequency or duty cycle in when in the frequency voltage or current function When in the voltag...

Page 5: ...urrent AC or DC will appear on the LCD display AC and DC Current Measurements Observe all safety precautions when working on live voltages WARNING Observe all safety precautions when working on live v...

Page 6: ...ible tone will sound If the circuit is above 400 the LCD display will indicate OL The resistance will be shown on the LCD display if it is below 400 Wire 10 WARNING Operation 1 Set the rotary function...

Page 7: ...h a fresh 9V battery 5 Install battery door and tighten screws WARNING TO AVOID ELECTRICAL SHOCK REMOVE ALL INPUTS BEFORE OPENING THE CASE TO PREVENT FIRE INSTALL FUSE WITH AMP VOLT RATING SHOWN 9V BA...

Page 8: ...Fuse DC Current Auto ranging 400 0uA 4000uA 40 00mA 400 0mA 10A 0 1uA 1uA 10uA 100uA 10mA 1 0 of rdg 5 digits 2 5 of rdg 3 digits Maximum Input 4000uA DC on uA range 400mA DC on mA range 10A DC on 10A...

Page 9: ...tenance or repair operation outside of specifications or abnormal handling of the product Southwire s sole liability and the purchaser s exclusive remedy for any breach of this warranty is expressly l...

Reviews: