background image

4

Maintenance

This Multimeter is designed to provide years of dependable service, if the 

following care instructions are performed:
1. KEEP THE METER DRY. If it gets wet, wipe it off.
2. USE AND STORE THE METER IN NORMAL TEMPERATURES. Temperature

    extremes can shorten the life of the electronic parts and distort or melt

    plastic parts.
3. HANDLE THE METER GENTLY AND CAREFULLY. Dropping it can damage the

    electronic parts or the case.
4. KEEP THE METER CLEAN. Wipe the case occasionally with a damp cloth.

    DO NOT use chemicals, cleaning solvents, or detergents.
5. USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE.

    Remove old or weak batteries so they do not leak and damage the unit.
6. IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME, the 

    batteries should be removed to prevent damage to the unit.

FCC COMPLIANCE

Users of this product are cautioned not to make modifications or changes that are not approved by

Southwire Company, LLC. Doing so may void the compliance of this product with applicable FCC requirements

and may result in the loss of the user’s authority to operate the equipment.

This device complies with Part 15 of the FCC rules and with RSS-210 of Industry Canada. Operation is subject to the 

following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any 

interference received, including interference that can cause undesired operation.

FCC Digital Emissions Compliance

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of 

the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential 

installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in 

accordance with the instructions, may cause harmful interference to radio communications. However, there is no 

guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference 

to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged

to try to correct the interference by one or more of the following measures:

• Reorient or relocate the radio or television receiving antenna.
• Increase the separation between the computer equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the radio or television receiver is connected.
• Consult the dealer or an experienced radio television technician for help.

Canadian Digital Apparatus Compliance

 

CAN ICES-3 (B)/NMB-3(B)
   

Insulated Tip On

Insulated Tip Removed

3

Potential danger. Indicates the user must refer to the manual for important safety information

Indicates hazardous voltages may be present

Equipment is protected by double or reinforced insulation

Indicates the terminal(s) so marked must not be connected to a circuit where the

voltage with respect to earth ground exceeds the maximum safety rating of the meter 

MAX

600V

International Safety Symbols

Brief Description

Typical Applications

Category Rating

Single phase receptacles 

and connected loads 

Three phase circuits and 

single phase lighting 

circuits in commercial 

buildings

Connection point to 

utility power and 

outdoor conductors  

- Household appliances, power tools

- Outlets more than 30ft (10m) from a CAT III source

- Outlets more than 60ft (20m) from a CAT IV source
- Equipment in fixed installations such as 3-phase 

  motors, switchgear and distribution panels 

- Lighting circuits in commercial buildings

- Feeder lines in industrial plants

- Any device or branch circuit that is close to a CAT III source

- Primary distribution panels

- Overhead or underground lines to detached buildings

- Incoming service entrance from utility

- Outdoor pumps

CAT II

CAT III

CAT IV

The measurement category (CAT) rating and voltage rating is determined by a combination of the meter, test probes and any accessories connected to 

the meter and test probes. The combination rating is the LOWEST of any individual component.

Safety Category Ratings

WARNING: 

                            Operation is 

limited to CAT II applications 

when the insulated tips are 

removed from one or both test 

probes. Refer to Input Limits 

section in this manual for 

maximum voltage ratings. 

Test Leads

CAT IV  600V

CAT III 1000V  

CAT II

1000V

NOTE:

 The meter is waterproof 

and dust tight when test leads 

supplied with meter are 

inserted into input jacks.

IP67 Rating

A

ut

oselec

ting

Multimet

er

16030A

CA

T IV 600V

COM

Summary of Contents for 16030A

Page 1: ...briqu en Chine Product distributed by Produit distribu par Southwire Company LLC One Southwire Drive Carrollton GA 30119 2016 Southwire Company LLC All rights reserved Tous droits r serv s southwireto...

Page 2: ...d and with proper use will provide many years of reliable service WARNINGS Read understand and follow Safety Rules and Operating Instructions in this manual before using this meter The meter s safety...

Page 3: ...try to correct the interference by one or more of the following measures Reorient or relocate the radio or television receiving antenna Increase the separation between the computer equipment and rece...

Page 4: ...wer Off Autohold Flashlight Autoselecting Multimeter 16030A CAT IV 600V COM 5 Meter Description 1 Non contact AC voltage detector probe 2 LCD display 3 On Off button 4 Voltage Resistance Continuity se...

Page 5: ...d function To manually exit Autohold press and hold the Autohold button until the A HOLD symbol no longer appears on the display 8 1 Press the button to turn the meter on 2 Press the button until the...

Page 6: ...s the button to turn the meter on 2 Hold the detector probe close to the AC voltage being tested 3 If AC voltage within the specified range is present the indicator light will illuminate Non contact A...

Page 7: ...ing the battery or fuses be sure to secure the battery compartment door firmly to maintain the waterproof and dust proof integrity of the meter Loose or overtightened screws or an improperly seated o...

Page 8: ...RANTY This warranty is void if this product is used for rental purposes No product reseller is authorized to extend any other warranty on Southwire s behalf relating to this product and no such resell...

Page 9: ...fiable s il est utilis correctement AVERTISSEMENTS Il est important de lire de comprendre et de respecter les r gles de s curit et les instructions d utilisation avant d utiliser cet appareil Les cara...

Page 10: ...duire la dur e de vie de certains composants lectroniques les pi ces en plastique peuvent aussi se d former ou m me fondre 3 MANIPULEZ L APPAREIL AVEC DOUCEUR ET AVEC SOIN Les chutes et les chocs peuv...

Page 11: ...sistance continuit 5 Connecteur d entr e COM 6 Connecteur d entr e V 7 Bouton de maintien AutoHold lampe de poche 8 Indicateur de tension CA sans contact 9 Lampe de poche 1 2 4 7 8 9 6 5 3 6 Symboles...

Page 12: ...Appuyez sur le bouton pour allumer le multim tre Le r tro clairage de l cran LCD s teint apr s environ 2 minutes Pour activer nouveau le r tro clairage appuyez bri vement sur le bouton Appuyez sur le...

Page 13: ...que ou d autres sources d nergie peuvent activer le capteur de mani re al atoire Il s agit d un fonctionnement normal REMARQUE Le d tecteur n active le t moin lumineux que lorsqu une tension CA est pr...

Page 14: ...OR 1 5V AAAX2 WARNING Apr s le remplacement des piles v rifiez que le couvercle du compartiment des piles est bien fix pour maintenir l tanch it la poussi re et l eau Cette tanch it peut tre compromis...

Page 15: ...E Cette garantie ne s applique pas si le produit est acquis des fins de location Aucun revendeur de ce produit n est autoris tendre la port e de cette garantie au nom de Southwire et s il le fait Sout...

Page 16: ...sar este probador Las caracter sticas de seguridad del probador pueden no proteger al usuario si no se utilizan de acuerdo con las instrucciones del fabricante Aseg rese de que los cables de prueba es...

Page 17: ...apag ndolo se recomienda que el usuario trate de corregir la interferencia mediante una o m s de las siguientes medidas Reorientar o reubicar la antena de radio o televisi n Aumentar la separaci n en...

Page 18: ...tohold Linterna Autoselecting Multimeter 16030A CAT IV 600V COM 5 Descripci n del Metro 1 Sonda del Detector de Voltaje AC Sin Contacto 2 Pantalla LCD 3 Bot n de Encendido Apagado 4 Bot n de selecci n...

Page 19: ...e el bot n de para encender el probador La luz de fondo de la pantalla LCD se apagar despu s de apr x 2 minutos Para encender nuevamente la luz de fondo pulse moment neamente el bot n de Para apagar e...

Page 20: ...ctricidad est tica u otras fuentes de energ a pueden activar de forma aleatoria el sensor Esta es una operaci n normal NOTA El detector s lo activa la luz indicadora cuando el voltaje AC est presente...

Page 21: ...robador antes de retirar la cubierta de la bater a ADVERTENCIA Reemplazo de la Bater a TO AVOID ELECTRIC SHOCK REMOVE ALL INPUTS BEFORE OPENING BATTERY DOOR 1 5V AAAX2 WARNING 12 Especificaciones cont...

Page 22: ...NCUMPLIMIENTO DE ESTA GARANT A Esta garant a no ser v lida si el producto se utiliza para prop sitos de alquiler Ning n vendedor de productos est autorizado a extender la garant a a nombre de Southwir...

Reviews: