9
1. Press the button to turn the meter on.
2. Press the button until the “ ” symbol
appears on the display.
3. Insert the black test lead into the
COM
input
jack and the red test lead into the
V
Ω
input jack.
4. Touch the test lead probes to the device or wire
under test.
5. A beeper will sound if the resistance is approx.
50
Ω
or less and the resistance value will be
shown on the LCD display.
WIRE
Continuity Measurements
Never test continuity on a live circuit.
WARNING:
Operation cont.
COM
COM
NOTE:
The meter will automatically switch to voltage
if connected to a live circuit (> 2.6V)
Autoselecting
Multimeter
16030A
CAT IV 600V
COM
Aut
oselec
ting
Multimet
er
16030A
10
Operation cont.
1. Press the button to turn the meter on.
2. Hold the detector probe close to the AC
voltage being tested.
3. If AC voltage within the specified range
is present, the indicator light will illuminate.
Non-contact AC Voltage Detection: 100V to 600V
Risk of Electrocution. Before use, always test the
Voltage Detector on a known live circuit that is within the defined detection
range to verify proper operation.
WARNING:
NOTE:
Insulation type and thickness, and distance from the voltage source
and other factors may effect operation. Use other methods to verify live
voltage if there is any uncertainty.
NOTE:
The detector is designed with high sensitivity. Static electricity or other
sources of energy may randomly activate the sensor. This is normal operation.
NOTE:
The detector only activates the indicator light when AC voltage is
present. It does not indicate the voltage level on the LCD display.