AR-1203P Installation Manual
SOYAL
Technology Co., Ltd.
www.soyal.com
VI.
Power input setting
※ Caution:Please DO NOT connects the incorrect voltage to lock; otherwise, this will void products warranty.
VII.
Auto relocking timer setting: (0/3/6/9 sec.)
VIII.
Indicators-
LED and BUZZER identification as following chart:
Indicators
LED
BUZZER
Waiting for locking
Red LED lights up
None
Door locking time delay
Green LED flashes once per second
None
Detecting lock
Red LED flashes once per second
None
Locked well
Green LED flashes once every two seconds
2 beeps per seconds
Fail to lock
Red LED flashes once per second for 10 seconds
1 beep per second for 10 seconds
Keeping locking
Red LED flashes once every two seconds for 30 seconds
1 beep every 2 seconds for 30 seconds
Forced entry (Alarm)
Green and Red LED's flash alternately every 0.5 sec. for 30 seconds Keeps beeping for 30 seconds
Remote Release(Exit Switch) Red LED flashes once per second for 3 seconds
1 beep per second
IX.
System functions :
By logical program systems to control the bolt lock; It has auto-detective functions
including bolt fixed position, door locking time delay, locked well and forced entry
(alarm)and remote release (exit switch). (*)-See “I. Order Information”
1. Standby (Power on the system when door is open): If you close the door, the system will receive an induction and the time delay (0/3/6/9 sec.) will
start to count, and then the auto-detective function will execute the following movements:-
a. However, the period of time delay, if door is opened, the bolt will automatically retract and the systems will return to standby.
b. After a time delay (0/3/6/9 sec.), if door is closed, the bolt will automatically extend into the “Detecting lock” and execute the following functions.
c. After “Detecting lock” (or system received an induction of “Locked well”-(*)), the bolt will automatically extend and the lock will be held.
(*)d. After “Detecting lock”, if the bolt is out and not in the right position-“Fail to lock”, the users can see bicolor indicators or listen to the “warning
buzzer” and push the door in the right position, the bolt will automatically extend and the lock will be held.
(*)e. After “Fail to lock”, the bolt will enter into “Keeping locking” mode and re-lock every 30 seconds, the users can see bicolor indicators or listen to
the “warning buzzer” and push the door in the right position, the bolt will automatically extend and the lock will be held.
2. Unlock (In locking, push the exit-switch) - “Remote Release”: The bolt will automatically retract, after 3 seconds, if the door is closed, the time delay
(0/3/6/9 sec.) will reset and count and then execute the following functions.
(*)3. Forced entry (Alarm): Indicates an error status or forced entry, the system can alarm bell given (30 seconds).
X.
Installation Diagram:
1
2
3
4
1
3
4
5
7
6
8
2
A. Electic Bolt lock body
A. 12VDC input setting:
Jumper setting as shown on below:
PIN-1 and PIN-2 closed
PIN-3 and PIN-4 closed
1 2 3 4
B. 24VDC input setting:
Jumper setting as shown on below:
PIN-2 and PIN-3 closed
1 2 3 4
(Exit switch time delay)
ON
1 2
0 sec.
1 2
1 2
1 2
0 sec.
3 sec.
3 sec.
6 sec.
6 sec.
9 sec.
9 sec.
ON
ON
ON
(Door locking time delay)
※ Caution:
You need to set power off (or power
disconnect) while s
etting the auto
relocking timer.
- 2 -