background image

 
 

AR-1203P Installation Manual 

 

SOYAL

 

Technology  Co.,  Ltd.

www.soyal.com 

VI.

 

Power input setting 

 
 
 
 

※ Caution:Please DO NOT connects the incorrect voltage to lock; otherwise, this will void products warranty. 

VII.

 

Auto relocking timer setting: (0/3/6/9 sec.)   

 

 

 

VIII.

 

Indicators-

LED and BUZZER identification as following chart:

 

Indicators 

LED 

BUZZER 

Waiting for locking 

Red LED lights up 

None 

Door locking time delay 

Green LED flashes once per second  

None 

Detecting lock 

Red LED flashes once per second 

None 

Locked well 

Green LED flashes once every two seconds  

2 beeps per seconds 

Fail to lock 

Red LED flashes once per second for 10 seconds 

1 beep per second for 10 seconds 

Keeping locking 

Red LED flashes once every two seconds for 30 seconds 

1 beep every 2 seconds for 30 seconds

Forced entry (Alarm) 

Green and Red LED's flash alternately every 0.5 sec. for 30 seconds Keeps beeping for 30 seconds 

Remote Release(Exit Switch)  Red LED flashes once per second for 3 seconds 

1 beep per second 

IX.

 

System functions :

 

By logical program systems to control the bolt lock; It has auto-detective functions 

including bolt fixed position, door locking time delay, locked well and forced entry
(alarm)and remote release (exit switch). (*)-See “I.    Order Information” 

1. Standby (Power on the system when door is open): If you close the door, the system will receive an induction and the time delay (0/3/6/9 sec.) will 

start to count, and then the auto-detective function will execute the following movements:- 

a. However, the period of time delay, if door is opened, the bolt will automatically retract and the systems will return to standby.  

b. After a time delay (0/3/6/9 sec.), if door is closed, the bolt will automatically extend into the “Detecting lock” and execute the following functions. 

c. After “Detecting lock” (or system received an induction of “Locked well”-(*)), the bolt will automatically extend and the lock will be held. 

(*)d. After “Detecting lock”, if the bolt is out and not in the right position-“Fail to lock”, the users can see bicolor indicators or listen to the “warning 

buzzer” and push the door in the right position, the bolt will automatically extend and the lock will be held. 

(*)e. After “Fail to lock”, the bolt will enter into “Keeping locking” mode and re-lock every 30 seconds, the users can see bicolor indicators or listen to 

the “warning buzzer” and push the door in the right position, the bolt will automatically extend and the lock will be held. 

2. Unlock (In locking, push the exit-switch) - “Remote Release”: The bolt will automatically retract, after 3 seconds, if the door is closed, the time delay 

(0/3/6/9 sec.) will reset and count and then execute the following functions. 

(*)3. Forced entry (Alarm): Indicates an error status or forced entry, the system can alarm bell given (30 seconds).

 

X.

 

Installation Diagram: 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
   

1

2

3

4

1

3

4

5

7

6

8

2

A. Electic Bolt lock body 

A. 12VDC input setting:   

Jumper setting as shown on below: 
PIN-1 and PIN-2 closed 
PIN-3 and PIN-4 closed

 

1 2 3 4

B. 24VDC input setting:   

Jumper setting as shown on below: 

PIN-2 and PIN-3 closed 

1 2 3 4

(Exit switch time delay) 

ON

1 2

0 sec.

1 2

1 2

1 2

0 sec.

3 sec.

3 sec.

6 sec.

6 sec.

9 sec.

9 sec.

ON

ON

ON

(Door locking time delay) 

※ Caution:

You need to set power off (or power 

disconnect) while s

etting the auto 

relocking timer. 

- 2 -