background image

AR-323-D

V200623

ACCESS & INDUSTRIAL CONTROL

Smart Digital Door Lock

RF Card

1

2 3

4

5 6

7

8
0 #

*

9

A

B

B

C

A

A

B

B

C

C

D

Handle hole

Deadbolt knob hole 

Cylinder hole

Cable hole

9.Elastic Spring

10.Allen Wrench

X  CN1

Y  CN2

Z  CN3

5.Cylinder Lock

6.Mechanical Key

7. Waterproof Strap

8.Handle Screw

1.Mortise

2.Mortise Plate (mounted)

3.Spindle of Knob

4.Spindle of Handle

5. 

1. 

(1)

(1)

4. 

3. 

2. 

(2) 

7. 

(7)

8. 

8. 

9. 

9. 

7. 

6. 

10. 

Cross-Head screw driver 

Tools

16.

17.

18.

STEP 1 : Stand-alone: Install battery before the upper 

               cover of back panel.

STEP 2 :Install the lower cover of back panel as above 

              picture shown.

Using (10) Allen Wrench, Fasten the (8)Handle Screw into 

(E)Handle Screw Hole up until it reached Front Panel and 

properly fasten.

※ 

Note: Before tightening the screw, make sure the 

              Waterproof Strap is fit in the Back and Front 

              Panel, Back Panel and Front Panel position is in 

              correct position

1. Peel off “Strike Sticker” and paste into the desired 

    spot for installation

2. Start making the hole drilling based on the hole 

    dimension on the sticker

3. Remove the sticker after hole drilling is finished

STEP 1 : Embed the Strike Box into the hole

STEP 2 : Embed the Strike Plate on Strike Box and 

               fasten with  Screws

STEP 3 : Installation of Strike is finished.

1.

2.

3.

1

1

5.87

20*10

11

5.87

20*10

115

.8

7

20*10

Paste hole-sticker on the door properly and 

make cuts depending on hole-stickers 

dimension.

Install cylinder into mortise , use the screw to 

fix cylinder properly 

Fasten (5) Cylinder Lock into      hole 

Place back  (2) Mortise Plate into 

Mortise lock body (original position)

Remove (2) Mortise Plate from (1) Mortise 

lock body

Embed (1) Mortise into the hole

Insert two of the  (4)  Spindle of Handle into       

       hole

Installation front and back panel.

Strike components installation and 

fasten Screws

Waterproof strap and fixing screw

Waterproof Strap

Strike hole drilling

※ 

Note :

1

Only make "deadbolt knob hole" from inner door to   

    mortise, don't cross to outer door.

2

Make sure accurate position & right hole direction of    

    striker plate; before making cuts, latch bolt position can 

    be made firstly. 

3

Networking mode : Additional hinge cuts is required for    

    PC connection.

STEP 1 :  Insert the (1)

 

Mortise into the hole.

STEP 2 : There is a CN3 cable connecting (1) Mortise with 

               Front Panel, make sure the cable is out from       hole. 

STEP 3 : Next, make sure that the external power and        

               communication cable to CN1 is ready and wired on site

Separate (2)

 

Mortise Plate from (1) Mortise lock by 

unfasten the screw that has already mounted. It is 

because the first step to be done is to fasten Screws 

between (1) Mortise and door and mounted (2) 

Mortise Plate is closing the path of it.

1

1

5.87

20*10

4.

8.

9.

5.

6.

7.

12.

※ 

Important:

1. The depth of the  (5) Cylinder Lock installation has    

    already fixed. The screw position must meet with the 

    hollow part of the (5) Cylinder Lock

 

2.

 

We suggest making sure that the upper bolt and the 

    lower bolt functions correctly before fixing the screw. 

    Testing can be made using the mechanical key by 

    rotating it to left and right and it will move bolt position       

    means it works properly. 

1. Make sure the key lock hole on the topside,and fixed 

 tightly.

2. Please confirm the key can control 2 bolt.

Fasten the (1) Mortise lock into the door 

with Screws on both side

※ 

Note: The crooked part is in the Back Panel position,     

               and the flat surface is in “ 1 ”Mortise position.

※ 

Note: The crooked part is in the hole position, and the 

               flat surface is facing out.

Provided (7) Waterproof Strap is recommended to apply 

for waterproof function and to preserve the lock durability 

from door opening and closing 

STEP 1: Provided (7) Waterproof Strap is recommended to 

               apply for waterproof function and to preserve the 

               lock durability from door opening and closing 

STEP 2: Put in (9)Elastic Spring into (8)Handle Screw (this 

               is optional but suggested for durability purpose)

STEP 1 

STEP 1 

STEP 2

STEP 2

STEP 2

E

E

E

D

F
G

Handle screw hole

Mortise hole 

Strike hole

4. 

14.

STEP 1 : Disassemble the upper cover (sliding type)

STEP 2 : Disassemble the lower cover (buckle type) 

Disassemble Back Panel cover

STEP 1 

STEP 2

Fix Front and Back Panel position

15.

1

2 3

4

5 6

7

8
0 #

*

9

 Front panel

Back panel

Connect (1) Mortise to Front Panel 

10.

STEP 1 :  Connect the Front Panel CN3 Connector of 

                Mortise  to (1) Mortise 

STEP 2 : Bring CN2 Connector of Reader into      Cable 

               Hole to be connected to Back Panel later

STEP 3 : Plug in (4) Spindle of Handle on the mortise into     

               Handle Hole

Front panel

STEP 1

STEP 2

STEP 3

Connector

of mortise

CN3

CN3

STEP 1

STEP 3

STEP 2

D

D

D

D

A

C

A

C

(5) 

(2)

(4)

(4)

 

PART 1: MORTISE

CN1

CN2

CN2

(1)

(1)

(4)

Connect  (1) Mortise to Back Panel

13.

STEP 1 : Connect the CN1 Power and Communication    

               Cable to DC power and RS485 communication 

               (refer to the ‘Wiring’ Section)

STEP 2 : Continuation from Step 10-2 connect the cable 

               from      Cable Hole to CN2 Connector of Reader 

              of the  Back Panel

STEP 3 : Fasten (3) Spindle of Knob from     Deadbolt Knob 

               Hole of (1) Mortise into      Deadbolt Knob Hole of 

               the Back Panel

1

2 3

4

5 6

7

8
0 #

*

9

CN1

CN2

STEP 3

STEP 2

STEP 1

D

B

B

B

(3) 

CN3 CN2

PART 2: HANDLE PANEL(Front Panel)

PART 3:  STRIKE

Front Panel

Back Panel

11.

Cover Cylinder Lock by sliding up the the lower cover and 

finish installation

Place the lower cover for the Front Panel

STEP 3

1

2 3

4

5 6

7

8
0 #

*

9

PART 3: HANDLE PANEL(Back Panel)

(7)

(8)

(9)

(8)

(9)

Back panel

A

Summary of Contents for AR-323D

Page 1: ...ower DC0V Power DC12V Wire Application Door Handle Direction RH Right Push LH Left Push RHR Right Pull Before installation please check which door hand you require LHR Left Pull Door Handle Mortise Lock Sticker Strike Sticker 1 Mortise 2 Mortise Plate mounted 3 Spindle of Knob 4 Spindle of Handle x2 11 Screw x2 5 Cylinder Lock 6 Mechanical Key x2 7 Waterproof Strap x2 8 Handle Screw x2 9 Elastic S...

Page 2: ... make cuts depending on hole stickers dimension Remove 2 Mortise Plate from 1 Mortise lock body Note 1 Only make deadbolt knob hole from inner door to mortise don t cross to outer door 2 Make sure accurate position right hole direction of striker plate before making cuts latch bolt position can be made firstly 3 Networking mode Additional hinge cuts is required for PC connection Separate 2 Mortise...

Page 3: ...dy and wired on site 4 5 6 Important 1 The depth of the 5 Cylinder Lock installation has already fixed The screw position must meet with the hollow part of the 5 Cylinder Lock 2 We suggest making sure that the upper bolt and the lower bolt functions correctly before fixing the screw Testing can be made using the mechanical key by rotating it to left and right and it will move bolt position means i...

Page 4: ...tion and the flat surface is facing out Provided 7 Waterproof Strap is recommended to apply for waterproof function and to preserve the lock durability from door opening and closing Front panel Connect 1 Mortise to Front Panel 10 STEP 1 Connect the Front Panel CN3 Connector of Mortise to 1 Mortise STEP 2 Bring CN2 Connector of Reader into Cable Hole to be connected to Back Panel later STEP 3 Plug ...

Page 5: ...l cover STEP 1 STEP 2 Back panel CN1 X CN2 Y 1 Connect 1 Mortise to Back Panel 13 STEP 1 Connect the CN1 Power and Communication Cable to DC power and RS485 communication refer to the Wiring Section STEP 2 Continuation from Step 10 2 connect the cable from Cable Hole to CN2 Connector of Reader of the Back Panel STEP 3 Fasten 3 Spindle of Knob from Deadbolt Knob Hole of 1 Mortise into Deadbolt Knob...

Page 6: ... Front Panel Back Panel and Front Panel position is in correct position 1 Peel off Strike Sticker and paste into the desired spot for installation 2 Start making the hole drilling based on the hole dimension on the sticker 3 Remove the sticker after hole drilling is finished STEP 1 Embed the Strike Box into the hole STEP 2 Embed the Strike Plate on Strike Box and fasten with Screws STEP 3 Installa...

Page 7: ...ant to modify refer to password setting 17 Add Tags Input 123456 or Master Code 11 SSSSS EEEEE OK e g Add User Address 00100 01254 Enter program mode 11 00100 01254 OK Add tag by presenting Delete tag by presenting Input 123456 or Master Code 22 1 Present the tag to Access Controller OK Input 123456 or Master Code 22 0 Present the tag to Access Controller OK Delete All Tags Input 123456 or Master ...

Page 8: ...y and Friday 08 1 09301620 01010100 Done M4 M8 Private PIN Card or PIN Enter program mode 12 UUUUU PPPP e g User Address 00001 and pass code 1234 input 12 00001 1234 Card and PIN Enter program mode 13 UUUUU PPPP e g User Address 00001 and pass code 1234 input 13 00001 1234 M6 Public PIN Card or PIN Enter program mode 15 PPPP Input 4 digit PIN default value 4321 PPPP 0000 cancel the function of sim...

Page 9: ...suddenly off then on Function Default Value M4 M6 M8 24 DDD Function Selection Value Application Default Value Auto Open without Presenting in Auto open Time Zone Alarm Output Lift Control Stop Alarm by pressing RTE Button or Closing the Door Doorbell 0 Disable 0 Alarm Output 0 None 0 Disable Networking Standalone Networking Standalone Networking Standalone Networking Standalone 001 002 064 128 1 ...

Page 10: ...e buffer time before entering arming mode 001 600 1 600 sec TTT the buffer time before the alarm is activated 001 600 1 600 sec SSSSS EEEEE 00000 01023 00000 03000 for AR 725H SSSSS Starting User Address EEEEE Ending User Address N 0 1st time zone 1 2nd time zone HHMM Starting time hhmm ending time i e 08301600 08 30 to 16 00 7123456H 7 days of week Sun Mon Tue Wed Thu Fri Sat Holiday H 0 disable ...

Page 11: ...Networking Standalone Networking Standalone Networking Standalone Networking Standalone Networking Standalone Networking Standalone 001 002 003 004 016 032 064 128 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 2 1 323DMaster Test MASTER CARD Setting Use the MASTER CARD software Input the MASTER CARD number and press Write Cut off and tranmit the power Acti...

Reviews: