background image

AR-323-D

V200623

ACCESS & INDUSTRIAL CONTROL

- 6 -

Smart Digital Door Lock

RF Card

20    DDD

Function

Selection

Value Application

Default Value

Time Attendance
Auto Relock
Auto Open
Exit by RTE Button
Master Controller of Network
Entrance/Exit 
Anti-pass-back 

0: Yes

0: Disable

0: Disable

   

0: Disable

0: Slave

0: Exit

0: Disable

Networking
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking
Networking
Networking

001
002
004
016
032
064
128

   1: No
   1: Enable
   1: Enable

1: Enable

   1: Mater
   1: Entrance
   1: Enable

   

   

   

   

Enable: 

Enter program mode

 → 

Disable: 

Enter program mode

 → 

Factory Reset by its commands

When the device is Standalone (not networking)

Enter program mode

 → 

20

     

016

      → 

24

     

064

      → 

26

     

00000

     

01023

     

1

      → 

28

     

000

      → 

29

     

29

Note: if the Master Code has been changed, factory reset won't restore the Master Code to 123456.

Enable/Disable Arming status (for M4/M8; default value of arming PWD is: 1234) :

Standby Mode

Enter Program Mode

After door open

The normal procedure to open door

 → 

Input 4-digit arming PWD

 →

Do not open the door

     → 

Input 4-digit arming PWD

 → 

Present a valid card

※ 

[The normal procedure to open door] can refer to [Access Mode].

I. Setting Up the Arming

Alarm conditions:

1. Arming is enabled
2.Alarm system connected

Application:
1. Door open too long

: Door is open longer than door relay time plus door close time.

2. Force open

 (Opened without a valid user card): Access by force or illegal procedure.

3. Door position abnormal

: Arming is enabled and the power is suddenly off then on.

Function Default Value

M4 / M6 / M8

24    DDD

Function

Selection

Value Application

Default Value

Auto Open without Presenting 
in Auto-open Time Zone

Alarm Output/ Lift 
Control

Stop Alarm by pressing RTE 
Button or Closing the Door

Doorbell

0: Disable

0: Alarm Output

   

 0: None 

0: Disable

Networking/Standalone

Networking/Standalone

Networking/Standalone

Networking/Standalone

001

002

064

128

     1: Enable

     1: Lift Control

※ 

1: Yes

     1: Enable

28    DDD

Function

Selection

Value Application

Default Value

Double Door Control
Force Open Alarm Output

0: Disable

   

0: Disable

Networking/Standalone
Networking/Standalone

064

128

   1: Enable

1: Enable

※ 

M6: 

the user capacity can be 65535 because it only reads 5-digits 

CARD CODE

, while in 

M4/M8

 it reads both 

SITE CODE

 and 

CARD CODE

(10 digits).

Select the desired function, Weighted Value 

= Selection Index (0 or 1) x Value.

[e.g.] DDD (total weighted value of all 

functions): Enable "Auto Open" + "Exit by 

RTE Button" + "Anti-pass-back"=1*004 + 

1*016 + 1*128=148; As a result of that, the 

command will be 20    148    .

65,535

Mode

Networking/
Standalone

Standalone

Networking/
Standalone

Networking/

Standalone

User 

Capacity

Access Mode

M4

M6

M8

Yes

No

Yes

Yes

No

Yes

Yes

No

Yes

Yes

No

Yes

32

No

32

11

No

11

No

Auto-show 

Duty time

Event log 

Capacity

120 

Holidays

Duress  

Function

Time 

Zone

Lift 

Control

Anti-pass-

back

1.Card only
2.Card and PIN 

(4-digit PIN)

3.User Address 

(5-digit) 

+ PIN 

(4-digit Private PIN) 

1.Card only 

(using 17* command to set Arming PWD as 0000)

2.Card and PIN

 (4-digit public PIN= Arming PWD)

3.Card or PIN 

(4-digit public PIN= Duress code)

1.Card only
2.Card and PIN

 (4-digit Private PIN)

3.Card or PIN 

(4-digit Private PIN)

 

3,000

3,000

1,500

1,500

Summary of Contents for AR-323D

Page 1: ...ower DC0V Power DC12V Wire Application Door Handle Direction RH Right Push LH Left Push RHR Right Pull Before installation please check which door hand you require LHR Left Pull Door Handle Mortise Lock Sticker Strike Sticker 1 Mortise 2 Mortise Plate mounted 3 Spindle of Knob 4 Spindle of Handle x2 11 Screw x2 5 Cylinder Lock 6 Mechanical Key x2 7 Waterproof Strap x2 8 Handle Screw x2 9 Elastic S...

Page 2: ... make cuts depending on hole stickers dimension Remove 2 Mortise Plate from 1 Mortise lock body Note 1 Only make deadbolt knob hole from inner door to mortise don t cross to outer door 2 Make sure accurate position right hole direction of striker plate before making cuts latch bolt position can be made firstly 3 Networking mode Additional hinge cuts is required for PC connection Separate 2 Mortise...

Page 3: ...dy and wired on site 4 5 6 Important 1 The depth of the 5 Cylinder Lock installation has already fixed The screw position must meet with the hollow part of the 5 Cylinder Lock 2 We suggest making sure that the upper bolt and the lower bolt functions correctly before fixing the screw Testing can be made using the mechanical key by rotating it to left and right and it will move bolt position means i...

Page 4: ...tion and the flat surface is facing out Provided 7 Waterproof Strap is recommended to apply for waterproof function and to preserve the lock durability from door opening and closing Front panel Connect 1 Mortise to Front Panel 10 STEP 1 Connect the Front Panel CN3 Connector of Mortise to 1 Mortise STEP 2 Bring CN2 Connector of Reader into Cable Hole to be connected to Back Panel later STEP 3 Plug ...

Page 5: ...l cover STEP 1 STEP 2 Back panel CN1 X CN2 Y 1 Connect 1 Mortise to Back Panel 13 STEP 1 Connect the CN1 Power and Communication Cable to DC power and RS485 communication refer to the Wiring Section STEP 2 Continuation from Step 10 2 connect the cable from Cable Hole to CN2 Connector of Reader of the Back Panel STEP 3 Fasten 3 Spindle of Knob from Deadbolt Knob Hole of 1 Mortise into Deadbolt Knob...

Page 6: ... Front Panel Back Panel and Front Panel position is in correct position 1 Peel off Strike Sticker and paste into the desired spot for installation 2 Start making the hole drilling based on the hole dimension on the sticker 3 Remove the sticker after hole drilling is finished STEP 1 Embed the Strike Box into the hole STEP 2 Embed the Strike Plate on Strike Box and fasten with Screws STEP 3 Installa...

Page 7: ...ant to modify refer to password setting 17 Add Tags Input 123456 or Master Code 11 SSSSS EEEEE OK e g Add User Address 00100 01254 Enter program mode 11 00100 01254 OK Add tag by presenting Delete tag by presenting Input 123456 or Master Code 22 1 Present the tag to Access Controller OK Input 123456 or Master Code 22 0 Present the tag to Access Controller OK Delete All Tags Input 123456 or Master ...

Page 8: ...y and Friday 08 1 09301620 01010100 Done M4 M8 Private PIN Card or PIN Enter program mode 12 UUUUU PPPP e g User Address 00001 and pass code 1234 input 12 00001 1234 Card and PIN Enter program mode 13 UUUUU PPPP e g User Address 00001 and pass code 1234 input 13 00001 1234 M6 Public PIN Card or PIN Enter program mode 15 PPPP Input 4 digit PIN default value 4321 PPPP 0000 cancel the function of sim...

Page 9: ...suddenly off then on Function Default Value M4 M6 M8 24 DDD Function Selection Value Application Default Value Auto Open without Presenting in Auto open Time Zone Alarm Output Lift Control Stop Alarm by pressing RTE Button or Closing the Door Doorbell 0 Disable 0 Alarm Output 0 None 0 Disable Networking Standalone Networking Standalone Networking Standalone Networking Standalone 001 002 064 128 1 ...

Page 10: ...e buffer time before entering arming mode 001 600 1 600 sec TTT the buffer time before the alarm is activated 001 600 1 600 sec SSSSS EEEEE 00000 01023 00000 03000 for AR 725H SSSSS Starting User Address EEEEE Ending User Address N 0 1st time zone 1 2nd time zone HHMM Starting time hhmm ending time i e 08301600 08 30 to 16 00 7123456H 7 days of week Sun Mon Tue Wed Thu Fri Sat Holiday H 0 disable ...

Page 11: ...Networking Standalone Networking Standalone Networking Standalone Networking Standalone Networking Standalone Networking Standalone 001 002 003 004 016 032 064 128 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 2 1 323DMaster Test MASTER CARD Setting Use the MASTER CARD software Input the MASTER CARD number and press Write Cut off and tranmit the power Acti...

Reviews: