AR-323-D
V200623
ACCESS & INDUSTRIAL CONTROL
- 6 -
Smart Digital Door Lock
RF Card
20 DDD
Function
Selection
Value Application
※
Default Value
Time Attendance
Auto Relock
Auto Open
Exit by RTE Button
Master Controller of Network
Entrance/Exit
Anti-pass-back
※
0: Yes
※
0: Disable
※
0: Disable
0: Disable
※
0: Slave
※
0: Exit
※
0: Disable
Networking
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking
Networking
Networking
001
002
004
016
032
064
128
1: No
1: Enable
1: Enable
※
1: Enable
1: Mater
1: Entrance
1: Enable
Enable:
Enter program mode
→
Disable:
Enter program mode
→
Factory Reset by its commands
When the device is Standalone (not networking)
Enter program mode
→
20
016
→
24
064
→
26
00000
01023
1
→
28
000
→
29
29
※
Note: if the Master Code has been changed, factory reset won't restore the Master Code to 123456.
Enable/Disable Arming status (for M4/M8; default value of arming PWD is: 1234) :
Standby Mode
Enter Program Mode
After door open
The normal procedure to open door
→
Input 4-digit arming PWD
→
Do not open the door
→
Input 4-digit arming PWD
→
Present a valid card
※
[The normal procedure to open door] can refer to [Access Mode].
I. Setting Up the Arming
Alarm conditions:
1. Arming is enabled
2.Alarm system connected
Application:
1. Door open too long
: Door is open longer than door relay time plus door close time.
2. Force open
(Opened without a valid user card): Access by force or illegal procedure.
3. Door position abnormal
: Arming is enabled and the power is suddenly off then on.
Function Default Value
M4 / M6 / M8
24 DDD
Function
Selection
Value Application
※
Default Value
Auto Open without Presenting
in Auto-open Time Zone
Alarm Output/ Lift
Control
Stop Alarm by pressing RTE
Button or Closing the Door
Doorbell
※
0: Disable
※
0: Alarm Output
0: None
※
0: Disable
Networking/Standalone
Networking/Standalone
Networking/Standalone
Networking/Standalone
001
002
064
128
1: Enable
1: Lift Control
※
1: Yes
1: Enable
28 DDD
Function
Selection
Value Application
※
Default Value
Double Door Control
Force Open Alarm Output
※
0: Disable
0: Disable
Networking/Standalone
Networking/Standalone
064
128
1: Enable
※
1: Enable
※
M6:
the user capacity can be 65535 because it only reads 5-digits
CARD CODE
, while in
M4/M8
it reads both
SITE CODE
and
CARD CODE
(10 digits).
Select the desired function, Weighted Value
= Selection Index (0 or 1) x Value.
[e.g.] DDD (total weighted value of all
functions): Enable "Auto Open" + "Exit by
RTE Button" + "Anti-pass-back"=1*004 +
1*016 + 1*128=148; As a result of that, the
command will be 20 148 .
65,535
Mode
Networking/
Standalone
Standalone
Networking/
Standalone
Networking/
Standalone
User
Capacity
Access Mode
M4
M6
M8
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
32
No
32
11
No
11
No
Auto-show
Duty time
Event log
Capacity
120
Holidays
Duress
Function
Time
Zone
Lift
Control
Anti-pass-
back
1.Card only
2.Card and PIN
(4-digit PIN)
+
3.User Address
(5-digit)
+ PIN
(4-digit Private PIN)
+
1.Card only
(using 17* command to set Arming PWD as 0000)
2.Card and PIN
(4-digit public PIN= Arming PWD)
+
3.Card or PIN
(4-digit public PIN= Duress code)
1.Card only
2.Card and PIN
(4-digit Private PIN)
+
3.Card or PIN
(4-digit Private PIN)
3,000
3,000
1,500
1,500