SOYAL
ACCESS CONTROL SYSTEM
®
AR-727 (H-V5)
V140701
N.C.
N.O.
COM
CTL
12V
E
BZ
RLED
GLED
WG 0
WG 1
12V
GND
1
2
3
4
5
6
7
8
1
2
3
4
5
6
12V
GND
Exit Switch
12V
GND
P2
P1
BZ
RLED
GLED
Door Output
WG 0
WG 1
WG-DS
WG-PB
7
8
EXIT
1
2
3
4
5
6
7
8
1 2 3
N.C.
N.O.
COM
CTL
12V
GND
PB
12V
GND
12V
GND
N.O.
12V
GND
12V
GND
DDR
P1
P6
AR-721RB
4
12V
N.C.
EXIT
RTE
Controller
Controller
Reader
RTE
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
Door Contact
Strengthen security with AR-721RB
Electric Bolt
Electric Bolt
Connect to Reader
Access programming mode
→
Add/Delete
→
Add -> RF-Learn
→
Input 5-digit user address
→
Input Tag Units(pcs)
→
Close Tag into RF Area
※
If adding a batch of
Sequential
tags, please input Tag Units(pcs) in the quantity of the tags and present the
tag with the
lowest card code
to the access controller.
1
2
Adding Tag by RF Learn Function
Tag Information
SITE CODE
CARD CODE
SITE CODE
CARD CODE
Adding and Deleting Tag
※
User capacity: 16384 (00000~16383)
Access programming mode
→
Add/Delete
→
Add -> Card ID
→
Input 5-digit user address
→
Input Site Code
→
Input Card Code
1
1
Adding Tag by Tag ID
Access programming mode
→
Add/Delete
→
Delete -> Addr
→
Input Starting address
→
Input Ending address
1
5
Deleting User Address
Access programming mode
→
User Setting
→
Access Mode
→
Input User Address
→
0: Invalid; 1: Card ; 2: Card or PIN; 3: Card & PIN
2
2
Setting up the access mode
Access programming mode
→
Add/Delete
→
Delete -> ID #
→
Input Site Code
→
Input Card Code
1
6
Deleting Tag by Tag ID
D. PIN Code
C. Initial setup
Access programming mode
→
User Setting
→
Password
→
Input
5-digit user address
→
Input 4-digit PIN (0001~9999)
→
Succeeded
Or via 701Client set it on Users screen
2
1
Node ID of Reader Setting
Access programming mode
→
Parameters[1]
→
Node ID
→
Input New Node ID : 1~254
(default value:001)
→
Main Door
Number : 0~255
→
WG1 Door Number : 0~255
→
Show UID
(0=No,1=WG,2=ABA,3=HEX)
→
Enable DHCP(0:No,1:En,2=Exit)
→
Succeeded
3
1
Language Setting
Access programming mode
→
Tools
→
Language
→
EN
→
Succeeded
→
Initial system...
5
1
0
F. Enable Voice Module (supporting version : F/w Ver 3.02
or later)
Hardware setting
Access programming mode
→
Tools
→
Ext. Comm Port
→
Voice
5
Software Setting
701 Server or
Programming
B. Entering and Exiting Programming Mode
Changing the Master Code
Access programming mode
→
Tools
→
Master Code
→
Input the
6-digit new master code
→
Succeeded
5
2
A. Keyboard Lock/ Unlock
Lock/ Unlock
Press and , and at the same time to lock keyboard.
Press again to unlock.
Entering
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456. If already changed the Master Code=
876112, input
876112
→
Access programming mode
P.S.If entering no instruction within
30 sec.
, it will automatically leave the
programming mode.
Exiting
Press the repeatedly
→
Quit or Quit and Arming (Please refer
to alarm / arming setting)
6
7
E. Setting up the alarm / arming
Conditions:
1. Arming enabled 2.Alarm system connected
Application:
1. Door open too long
: Door is open longer than door relay time plus
door close time.
2. Force open
(Opened without a valid user card): Access by force or
illegal procedure.
3. Door position abnormal
: When power is off and then on, reader
on arming before power off.
Step 1.
Click "Read."
Step 2.
Select "Card Reader"
in RS485-2 section.
Step 3.
Click "Write" to finish
the setting.
5
2