SP-6VA1S Mini Scaler Switcher
SP Controls, Inc. www.spcontrols.com
11
1.12
Firmware Update
SP-6VA1S supports firmware field-updating, by USB flash disk.
The Operation is:
1)
Copy the file “
MT23ATV.bin
” to a USB flash disk. (The “
MT23ATV.bin
” file is
provided/authorized by SP CONTROLS engineering department)
2)
Plug the USB flash disk to the SP-6VA1S USB port on its front panel.
3)
Press the button “MENU” for 15 seconds or more, until it comes out an update OSD.
4)
The SP-6VA1S will capture the new firmware from USB flash disk.
5)
After update to the new firmware, reboot and send the command “
0617%
” to restore
to factory settings.
6)
After that, reboot again.
Notice:
If send the RS232 command to restore factory setting is unsuccessful, please
change the baud rate to 115200 and try again.
Advanced Function