AC Voltage (Auto-ranging) 

Range

 

Resolution

 

Accuracy

 

2.000V

 

1mV

 

±1.2% of rdg ±  4 dgts

 

20

.

00V

 

10mV

 

±1.5% of rdg ±  3 dgts

 

200

.

0V

 

100mV

 

 

± 2

.

0% of rdg ±  4 dgts

 

600V

 

1V

 

 
Input Impedance: 10M

Ω

 

Frequency Range: 50 to 60Hz  
Maximum Input: 600V AC/DC rms

 

DC Current (Auto-ranging for uA and mA)

 

 
 

 

 

 

 

 

Overload Protection: 0

.

2A/600V 

Maximum Input

200mA DC or  200mA AC rms on µA/mA ranges 

Resistance (Auto-ranging)

 

 

      

 

 

 

 

Input Protection: 250V DC or 500V AC rms 

 

 

 

 

 

 

Range

 

Resolution

 

Accuracy

 

200 

.

0µA

 

0

.

1µA

 

± 1

.

0% of rdg  ±  3 dgts

 

2000µA

 

1µA

 

 

± 1

.

5% of rdg  ±  3 dgts

 

20.00mA

 

10µA

 

200 

.

0mA

 

100µA

 

Range

 

Resolution

 

Accuracy

 

200.0

Ω

 

0

.

1

Ω

 

±1.5% of  rdg  ±  4 dgts

 

2.000k

Ω

 

1

Ω

 

±1.2% of  rdg  ±  2 dgts

 

20.00k

Ω

 

10

Ω

 

 

±1.5% of  rdg  ±  2 dgts

 

200 

.

0k

Ω

 

100

Ω

 

2

.

000 M

Ω

 

1k

Ω

 

20.00M

Ω

 

10k

Ω

 

±2.0% of  rdg  ±  3 dgts

 

Summary of Contents for SP62015

Page 1: ...TIONS AND ATTACH RECEIPT TO MANUAL FOR FUTURE REFERENCE NOTE Proof of purchase must be retained by the customer as it will be required in the event of a claim under warranty AFTER SALES SUPPORT AUSTRA...

Page 2: ...A 6 Resistance Auto ranging 6 Diode Test 7 Temperature 7 Audible continuity 7 0peration 7 DC Voltage Measurements 8 AC Voltage Measurements 8 DC Current Measurements 8 AC Current Measurements 9 Resist...

Page 3: ...tor to a shock hazard Always recognize the meter voltage limit as stated on the front of the meter Never apply voltage or current to the meter that exceeds the specifiedmaximum SAFETY INFORMATION This...

Page 4: ...push button selection Continuity Diode AC DC Temperature C F 7 Non contact voltage SYMBOLS AND ANNUNCIATIONS Continuity BAT Low Battery Diode AUTO Auto Ranging AC Alternating Current or Voltage DC Dir...

Page 5: ...to power off Meter automatically shuts down after approx 15 minutes of inactivity Operating environment 0 C to S0 C 32 F to 122 F at 70 relative humidity Storage temperature 20 C to 60 C 4 F to 140 F...

Page 6: ...anging for uA and mA Overload Protection 0 2A 600V Maximum Input 200mA DC or 200mA AC rms on A mA ranges Resistance Auto ranging Input Protection 250V DC or 500V AC rms Range Resolution Accuracy 200 0...

Page 7: ...the meter is not in use This meter has Auto OFF that automatically shuts the meter OFF if 15 minutes elapse between uses If OL appears in the display during a measurement the value exceeds the range y...

Page 8: ...properdecimal point and value If the polarity is reversed the display will show minus before the value AC Voltage Measurements RISK OF ELECTRICAL SHOCK Could result in fatal electrical shock Risk of E...

Page 9: ...d symbol AC Current Measurements RISK OF ELECTRICAL SHOCK To avoid electric shock do not measure AC current on anycircuit whose voltage exceeds 250V AC Insert the black test lead banana plug into the...

Page 10: ...wires that have voltage in them Set the function switch to the position Insert the black lead banana plug into the negative jack COM and the red test lead banana plug into the positive jack Press the...

Page 11: ...touching the part under test until the reading stabilizes about 30 seconds Read the temperature in the display The digital reading will indicate the proper decimal point and value Warning To avoid el...

Page 12: ...the fuses and battery to make sure that they are still good and that they are properly inserted REPLACING THE FUSES RISK OF ELECTRICAL SHOCK To avoid electric shock disconnect the test leads from any...

Page 13: ...or normal wear and tear 1 2 Has been used in a manner other than for which it was originally designed 1 3 Has been tampered with or is otherwise than as supplied by SP Tools 1 4 Where any damage malfu...

Reviews: