9
SC-CF & SC-MP Service Manual
GFCI Trips!
3• If problem is not solved yet,
disconnect incoming power
lines.
If GFCI still trips, there must be
a cable problem.
Call an electrician!
4• If GFCI stops tripping, replace
GFCI.
5• If GFCI trips again, replace
Spa Pack.
If GFCI continues to trip carry out the following tests to correct
the problem:
1• If GFCI is properly connected, but
still tripping, (or Jumper #1 is set in
LC mode for 120 VAC systems),
unplug all outputs
including the
two blades of
the heater
and light cord.
2• If GFCI still trips, replace Spa Pack.
If it stops tripping, reconnect one
component at a time until GFCI
starts tripping. Replace defective
component.