30
SC-CF & SC-MP Service Manual
FLC Error Condition
An FLC error condition indicates a pressure switch problem. If
system detects any pressure when pump is off, an FLC error
condition will occur.
Power may remain On when the following steps are carried out.
2• Replace Spa Pack if FLO error
condition does not occur.
1• Disconnect pressure switch cable
on pressure switch.
If FLO error condition occurs when
pump is started, adjust pressure
switch or replace it.
(Refer to "How to Adjust the
Pressure Switch" section of this
manual.)