SC-CF & SC-MP Service Manual
HL Error Condition
If weather is very hot:
1• Remove spa cover (even during
the night). Start blower if spa is
equipped with one. Wait until
spa cools down (add cold water
if necessary).
If hot weather is not a factor:
2• Lower Set Point below current
water temperature.
The "Heater" indicator should
disappear from keypad display.
To shorten filter cycle duration:
5• Press and hold
Light
key for
5 seconds.
Display will
show a value
that represents the filter
cycle duration in hours.
Use
Down
arrow key
to lower
the number
of hours.
0 = no filtration
12 = continuous filtration
When the
desired setting
is displayed,
press
Light
key
again. The filter
cycle will start
immediately.
6•
If you do read 240 VAC,
replace Spa Pack.
If digital thermometer water temperature reading is 119
°
F or higher
and keypad display indicates correct temperature, carry out the
following tests.
3• Remove plastic cover. With
a voltmeter, read voltage
between the two heater
wires on the board.
4•
If you do not read 240 VAC,
pump may be overheating
water during filter cycle.
Shorten filter cycle duration.