Self Diagnostic Error Codes:
The Spa Power 750 controller has extensive self diagnostic
capabilities. In the event of a problem it will sound an alarm
and indicate an error number according to the nature of the
problem. The alarm can be muted by pushing the Light
button.
The error numbers and their meanings are listed below.
Error 1 (H2O) = PRIME FAILED
This is a special case. It is not necessarily a problem with
the Spa Power 750 itself but indicates that no water is
being detected in the heater housing. A push of the pump
button will run the pump for 10 seconds to try to get water
to the heater. If successful normal operation will resume. If
unsuccessful Error 1 (H20) will be indicated again.
Error 2 is not used.
Errors 3-8 are latching errors.
Operation will stop and will not continue until the controller
is reset (switched off and on again at the main power).
Error 3 = STUCK BUTTON
This error indicates that one of the buttons in the control
panel is stuck or has been held down for more than four
minutes. This may be caused by water getting into the
panel or by damage to the control panel or its cable.
Error 4 = NO WATER SENSOR
This error indicates a problem with the optical water sensor
in the heater. It may be caused by the sensor being
disconnected or by damage to the sensor.
Error 5 = OVERTEMPERATURE
This error indicates that the digital temperature sensor in
the pool has detected a temperature of 45°C or more. This
is not necessarily a problem with the Spa Power 750 itself.
It might be caused by excessive pump use during hot
weather. In this case reduce the filtration time set.
Error 6 = THERMAL CUT OUT TRIPPED
This error indicates that the safety electromechanical over
temperature cut out on the heater has operated. This is not
necessarily a problem with the Spa Power 750 itself. It
might be caused by high temperatures during shipping or
by disconnection or failure of the pump. This error can be
cleared by waiting for the heater to cool below about 38°C
and switching the power off and on again.
Error 7 = STUCK RELAY
This error indicates a problem with the heater control
circuitry inside the unit.
Error 8 = NO TEMPERATURE DATA
This error indicates a problem with the digital temperature
sensor in the pool. It might be caused by the sensor being
disconnected or by damage to the sensor or its cable.
Pt No 916310
QUICK CARD USER GUIDE
SPA POWER 750
A&B
SPA CONTROLLERS
Please read these instructions carefully
before use
Spa-Quip (Australia) Pty Ltd
Unit 2A, 4 Hudson Ave
Castle Hill NSW 2154
Ph (612) 9634 5600, Fax (612) 9634 5900
Email: service@spa-quip.com.au
Web site: http://www.spa-quip.com.au
Manufactured By: Spa-Quip Ltd
Cnr Rothwell Ave & Albany Hwy
North Harbour Industrial Park
Auckland, New Zealand
Ph (649) 415 8622, Fax (649) 415 8621
Email: service@spa-quip.co.nz
Web site: http://www.spa-quip.co.nz
Dealer Stamp: