Range Hood Operations
Page 13
Control Panel Layout and Buttons Configurations:
This range hood is equipped with five electronic controls, a powerful centrifugal squirrel cage motor with two
aluminum filters, two bright 20W~12V or 40W~120/240V halogen lights and a filter clean reminder.
The five electronic buttons control the intensity of the Lights, Speeds (Quiet, Low and High) and Power (On/Off).
The Power Control (On/Off) offers startup, 3-minute delay or immediate power-off. The Light Control operates
independently from the Power Control (On/Off) and is not affected by the delay shutoff.
The aluminum filters are designed to deliver approximately 3 months of grease filtration between each cleaning.
The Filter Clean Reminder is set to turn ON after 100-hours of fan operation have elapsed since the installation
of cleaned or new filters. The timer for this reminder light will reset each time the filter is removed and the trigger
is released.
Power Control
(On/Off)
Light Control
Filter Clean
Reminder
Quiet
Speed
Low
Speed
High
Speed
Filter Clean Reminder
Timer Reset Trigger
Turning Fan ON:
Always turn fans ON couple minutes before cooking to establish air flow and allow fans to run for a few minutes
after cooking for cleaner air in the kitchen. The Power Control (On/Off) button must be pressed before a Speed
Control button can be activated.
NOTE: The light setting will not be affected by the Power Control (On/Off) button.
With the range hood is OFF, press the Power Control (On/Off) button once. The LED on the Power Control
•
button will be illuminated.
While the Power Control LED is illuminated, press one of the three speed control button (Quiet, Low and
•
High) to activate the desired speed (the LED on the speed control button will turn on).
To change the fan speed, press another speed control button. The LED on the speed control button will be-
•
come illuminated accordingly.