- 3 -
INSTALLATION
• A minimum of 6” round (standard for this range hood) must be used to
maintain maximum airflow efficiency.
• Always use rigid type metal/aluminum ducts if available to maximize airflow
when connecting to provided duct.
• ALWAYS, when possible, reduce the number or transitions and turns. If long
duct run is required, increase duct size from 6” to 7” or 8”. If a reducer is used,
install a long reducer instead of a pancake reducer.
Reducing duct size will restrict airflow and decrease airflow, thus reduce duct
size as far away from open in gas possible.
• If turns or transitions are required: Install as far away from opening and as
far apart, between 2, as possible.
• Minimum mount height between stove top to hood bottom should be no less
than 27-inch*.
• Maximum mount height between stove top to hood bottom should be no
higher than 30-inch*.
• It is important to install the hood at the proper mounting height. Hoods
mounted too low could result in heat damage and fire hazard; while hoods
mounted too high will be hard to reach and will loose its performance
and efficiency.
• If available, also refer to stove top manufacturer’s height clearance
requirements and recommended hood mounting height above range.
* Due to different ceiling height configurations, recommended height may not
be applicable.