Dongle Cables
24
SPARC T5-1B Server Module Installation Guide • May 2014
Related Information
■
■
■
“Handling Precautions” on page 20
■
■
“Tools Needed for Installation” on page 22
Dongle Cables
For setup, testing, or service purposes, you can connect cables directly to the server module SP
by first attaching a dongle cable to the UCP on the front panel of the server module.
Caution -
Dongle cables should be removed when not in use. These cables have not been
evaluated for electromagnetic compatibility compliance and are not to be used during normal
system operation.
There are two types of dongle cables you can use:
■
UCP-3
– Three-connector dongle cable (preferred) ships with the server module. Use the
RJ-45 connector to connect to the server module SP.
■
UCP-4
– Four-connector dongle cable (previous version). You must use the DB-9 connector
to connect to the server module SP. The RJ-45 connector is not supported. If you need an
RJ-45 connection, attach an optional DB-9-to-RJ-45 adapter to the DB-9 connector.