Insert the Server Module Into the Chassis
Installing the Server Module
31
Insert the Server Module Into the Chassis
There are limitations on the total number of server modules that you can install in a modular
system. Refer to the
SPARC T5-1B Server Module Product Notes
, Configuring Server Module
Power Usage for details.
1.
If you have not done so, prepare the modular system and server module.
“Prepare the Modular System and Server Module” on page 29
2.
If you have not done so, install any optional components.
“Install Optional Components” on page 30
.
3.
Remove the protective cover from the rear connector of the server module.
4.
Be prepared to communicate with the server module after completing the
physical installation.
As soon as you insert the server module in a powered modular system, power is supplied to
the server module and the SP generates messages. If you want to see these messages, be ready
to connect using one of the methods in
“Plan Communication With the Server Module During
5.
Locate the slot in the chassis where you plan to install the server module.
A filler panel should remain in this slot until just before you are ready to insert the server
module. All slots should remain filled with server modules or filler panels to ensure correct air
flow, heat, and electromagnetic interference conditions in the modular system.
6.
Remove the filler panel from the selected chassis slot.
Pull down the ejector arm of the filler panel, then pull the panel straight out of the chassis.
Caution -
Be ready to insert the server module within 60 seconds of removing the filler panel.
Summary of Contents for E35202-05
Page 1: ...Part No E35202 05 May 2014 SPARC T5 1B Server Module Installation Guide ...
Page 2: ......
Page 8: ...8 SPARC T5 1B Server Module Installation Guide May 2014 ...
Page 14: ...14 SPARC T5 1B Server Module Installation Guide May 2014 ...
Page 18: ...18 SPARC T5 1B Server Module Installation Guide May 2014 ...
Page 28: ...28 SPARC T5 1B Server Module Installation Guide May 2014 ...
Page 34: ...34 SPARC T5 1B Server Module Installation Guide May 2014 ...
Page 58: ...58 SPARC T5 1B Server Module Installation Guide May 2014 ...
Page 62: ...62 SPARC T5 1B Server Module Installation Guide May 2014 ...